As the highest performer of the J high-performance series, the J-E BioSafe Centrifuge generates maximum speeds up to 21,000 RPM (53,300 x g) and offers the capacity of processing up-to 4 liters in under 10 minutes. The J-E's high torque switched reluctance (SR) direct drive achieves faster acceleration and deceleration with gentle precision that delivers the fastest separations in the shortest run times, performance unattainable by standard high-speed centrifuges. The J-E is compatible with the comprehensive J series standard and BioSafe-certified rotors and labware for sample sizes from a few microliters up-to 4 liters. For total versatility, select the new AllSpin JS-5.3 high capacity swinging bucket rotor system, which processes up-to twenty-four 96-well microtiter plates and offers the flexibility of processing a variety of sample sizes in bottles from 4 x 500 mL to 96 x 17 mm tubes. The J-E’s compact build gives you the freedom to place it wherever you need it. Using CFC-free refrigerants and a maintenance-free vacuum pump to partially remove friction-generating air molecules, the J-E offers better temperature control (-10° C - +40° C in 1° C increments), a more energy efficient system, lower heat output (< 6,900 BTUs) and quieter operation for a comfortable, productive work environment.

Specifications

Platform Avanti
Max Speed 21,000 rpm
Max g-Force to 53,300.00 x g
BioSafe No
Acceleration 2 profiles, Maximum (full accleration to set speed) & Slow
Deceleration 3 profiles (max, slow & off (coast)
Speed Control ± 50 rpm of set speed
Timed Run 1 minute-99 hours, 59 minutes or Continuous Hold
Max Capacity Volume Range 1 x 4 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 2 kW (6,900 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Drive Type Cooling SR Drive* / Air cooled
Time (Actual Display) Indicates run time remaining (timed run) or elapsed time (hold run)
Temperature Range(s) 10°C - 40°C in 1 degree increments
Rotor Chamber Diameter cm / in
Zonal Capability Yes
Installation Category II
Sterile Available
Environmental Conditions -10°C to 40°C in 1° increments
Humidity Restrictions < 95% (non-condensing)
Material(s) Steel, Structural Foam
Finish Control Panel: Silicone elastomer, Top Surface: Urethane paint, Other surfaces: General purpose paint
Weight 267.4 kg / 589.5 lb
Width 63.5 cm / 25 in
Depth 80.0, cm / 80.0, in
Height 91.4 cm (152.4 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output < 64 dBa
Additional Information Sterile available
Power Requirements 220/380 VAC, 50/60 Hz
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.