The Microfuge® 16 offers fast, powerful micro-centrifugation in an easy-to-use, compact design. Powerful--spins quietly at 16,163 x g (14,800 rpm) for fast pelleting or isolation of DNA, RNA, proteins and viruses Compact--fits easily in the tightest of workspace environments with a height under 7 inches and a footprint measuring 8.9 by 10.5 inches Productive--maximizes sample throughput with an innovative autoclavable 24-place rotor rated at 16,163 x g Reliable--features a brushless induction drive, safety auto-lock closure system and novel air-cooled rotor bowl for years of safe, high-performing operation Efficient--reduces process time with fast acceleration and deceleration rates Versatile--offers added flexibility to your protocols with choice of pulse, timed or continuous runs Simple--enables easy cleaning and maintenance Convenient--presents a large bright display with simple intuitive push button key entry and automatic lid release at sample run completion Adaptable--processes a wide array of microtubes from 0.2 to 2.2 mL with a choice of standard or soft start/stop programs

Specifications

Max Speed 14,800 rpm
Max g-Force 16,163.00 x g
Timed Run 10 sec to 99 min, 59 sec in 1 sec increments, continuous run or short run (pulse)
Max Capacity Volume Range x 52.8 mL
Refrigeration System No
Max Heat Dissipation 0.1 W (347 BTU/hr)
Temperature Range(s) Ambient temperature range: 4° to 40°C
Installation Category II
Humidity Restrictions <80% (non-condensing)
Weight 6.4 kg / 14.1 lb
Width 22.6 cm / 8.9 in
Depth 26.6 cm / 10.5 in
Height 17.6 cm / 6.9 in
Max Noise Output <60dBa
Power Requirements 50/60 Hz, 110-120 VAC, 95 W
UNSPSC 41103901

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.