Echo Acoustic Liquid Handling for Synthetic Biology
Advantages of the Echo Liquid Handler in Synthetic BiologyCompared to Tip-based Liquid Handlers
|
![]() |
Gene Synthesis Workflow
The Echo Liquid Handler is an essential part of critical steps of any gene assembly workflow.
Echo Liquid Handler for Synthetic BiologyEcho acoustic liquid handling technology revolutionizes synthetic biology applications by using sound energy to enable highly accurate, fully automated, non-contact dispensing of fluids in nL to µL volumes. By reducing reaction volumes the Echo offers significant reagent costand time-savings while improving reaction efficiency. “(The Echo) is an extremely fast instrument…a significant savings in terms of time. We’ve been able to compress pipelines that take about 12 hours to about 3 hours.” Dr. Sunil Chandran, Amyris Biotechnologies |
How Does the Echo Move Liquids with Sound?Using the proprietary Dynamic Fluid Analysis technology, the Echo determines fluid composition and height, and the power needed to eject a precise volume of fluid into the destination well. This analysis happens in milliseconds, enabling precise and accurate transfer of nanoliter droplets into an inverted destination microplate. The desired transfer volumes are achieved by rapidly transferring multiple droplets per second. Transfers can be made from any well in the source to any well in the destination. The tip-less and contact-free technology of the Echo allows for miniaturization and automation of complex assays to dramatically reduce reagent cost and assembly time while improving data quality. |
Acoustic droplet ejection - The transducer is positioned below the source microplate well and emits focused sound energy repeatably to the meniscus of the fluid to be transferred. A stream of 2.5 or 25 nL droplets (model dependent) is reliably ejected into a well of an inverted destination microplate |
“We were able to successfully downscale PCRs and the popular one-pot DNA assembly methods, Golden Gate® and Gibson® assemblies, from the microliter to the nanoliter scale with high assembly efficiency, which effectively cut the reagent cost by 20- to 100-fold.
We envision that acoustic dispensing will become an instrumental technology in synthetic biology, in particular in the era of DNA foundries.” 1
Paulina Kanigowska, et al., JALA 2015
Reducing Reaction Costs while Improving Assembly Efficiency with Miniaturization
Gibson and Golden Gate Assembly: Cost-effectiveness and assembly efficiency comparison of different reaction volumes.1
Up to 82% Increase in Speed of Gene Assemblies and NGS Validation Steps
Colony Arraying Using the Echo Acoustic Liquid Handler
The Echo Liquid Handler has become the instrument of choice for highdensity and highthroughput fully automated colony arraying onto media/ agar plates. Hundreds of Petri dishes can be replaced with one densely spotted (up to 15636 spots) SBS standard plate filled with media and agar. |
Images courtesy of George McArthur, Ansa Bio |
Optimization and Rapid Processing of Cell-free Protein Expression Reactions with MiniaturizationCell-free transcription-translation (TXTL) or cell-free protein expression systems are versatile platforms for production of recombinant proteins within synthetic biology. Because in vitro protein synthesis is decoupled from cellular functions, the experimental cycle time can be greatly reduced, while the application range is expanded. Using the Echo Liquid Handler in combination with the cell-free protein expression master mixes enables rapid gene and protein expression projects that require high-throughput processing, flexibility and reproducibility, in a low-cost manner. The fast and any-well-to-any-well transfers of reagents and DNA pieces by the Echo allows for up to 10X faster reaction optimizations while lowering the reagent consumption and cost by at least 3-fold, compared to tip-based liquid handlers. |
![]() |
“The Echo 525 automates complex liquid aliquot rearray at high speeds and at miniaturized scales, saving significant time and money. It has proven to be extremely versatile and robust; my teams have used it to set up PCRs, cell-free protein synthesis reactions and biochemical assays, and even to array colonies of transformed bacteria on solid media. At Ansa, the Echo 525 is the workhorse for our automated DNA assembly platform.”
George McArthur, PhD, Head of Product, Ansa Biotechnologies
Low-Cost, Highly Efficient NGS Library Preparation
Cost-Effective and HighThroughput Colony qPCR
To avoid the impact of poor liquid handling performance, researchers traditionally use larger volumes of samples and reagents to prepare qPCR reactions. Echo Liquid Handlers enable miniaturization of these reaction volumes down to at least 2 µL, reducing costs and facilitating higher throughput. Furthermore, the tip-less and contact-free technology of the Echo reduces the chances of cross-contamination, as shown in the data to the right.
The data show that acoustic drop ejection technology reduces the chances of cross-contamination while generating tighter data, in terms of consistent Cq values.
Access Laboratory Workstation and Access Systems for Synthetic Biology Applications
Out-of-the-Box Automation for Echo Liquid Handlers
Combine the revolutionary performance of the Echo Liquid Handler with automated plate handling and integrated devices to create walk-away systems tailored for a range of synthetic biology applications. With the Access Workstation and Systems you can automate several steps of your synthetic biology workflow, including but not limited to: gene assembly, colony arraying, validation steps using colony qPCR or NGS methods, as well as any TXTL or cell-free protein expression techniques used for functional testing.
“At Codex DNA, the Echo 525 Liquid Handler and Access Workstation from Beckman Coulter Life Sciences has become an integral part of our BioXp™ system gene synthesis workflows. Processes that would take 8 hours with traditional liquid handlers now take less than 30 minutes with the Echo, enabling the construction of DNA variant libraries at an unprecedented scale. Moreover, the high accuracy and precision of non-contact acoustic transfers ensure that we’re delivering every oligonucleotide with the utmost confidence.”
John E. Gill, Senior Director of R&D, Codex DNA
Echo and Biomek: Better Together with a Large Dynamic Range from nL to mL
Echo Liquid Handlers
|
Biomek i-Series
|
Walk-away and High-throughput Applications
Faster, low-cost and high-throughput sample processing are achieved by combining the speed and low-volume accuracy and precision of Echo acoustic technology with the flexibility of Biomek i-Series workstations.
Echo Software Applications for Synthetic Biology Workflows
Echo Software Applications assist researchers in creating liquid handling protocols for specific applications. You can quickly create a variety of protocols off-line and use the built-in simulators to validate every transfer before running them live.
![]() |
Echo Cherry Pick
|
![]() |
Echo Plate Reformat
|
Echo Qualified Consumables for Synthetic Biology Workflows
The MicroClime Environmental Lid minimizes edge effects and preserves the concentrations of solutions in microplate wells. The novel fluid-absorbing matrix inside the lid creates a vapor barrier, protecting the sample from evaporation and greatly reducing edge effects, and therefore increasing the microplate efficiency by 37%. |
Beckman Coulter Life Sciences Service and Support
Maximize Your Instrument Performance
Timely service and preventive maintenance are essential for optimal instrument performance and data quality. Beckman Coulter Life Sciences offers a wide range of service contract options for the Echo Liquid Handler and Access Laboratory Workstation and Systems to fit every lab’s needs and budget. Our application scientists have extensive experience with genomic workflows and provide support and training on all our product offerings to help you maximize the use of your systems.
REFERENCES
- Kanigowska P, Shen Y, Zheng Y, Rosser S, Cai Y. Smart DNA Fabrication Using Sound Waves: Applying Acoustic Dispensing Technologies to Synthetic Biology. J Lab Autom. 2016;21(1):49-56. doi:10.1177/2211068215593754
- Shapland EB, Holmes V, Reeves CD, et al. Low-Cost, High-throughput Sequencing of DNA Assemblies Using a Highly Multiplexed Nextera Process. Shapland et al., ACS Synth. Biol., 2015. doi.org/10.1021/sb500362n
- Cain-Hom C, Pabalate R, Pham A, Patel HN, Wiler R, Cox JC. Mammalian Genotyping Using Acoustic Droplet Ejection for Enhanced Data Reproducibility, Superior Throughput, and Minimized Cross-Contamination. J Lab Autom. 2016;21(1):37-48. doi:10.1177/2211068215601637
- Bailey J, Eggenstein E, Lesnick J. Application Note: Miniaturization and Rapid Processing of TXTL Reactions Using Acoustic Liquid Handling. beckman.com/resources/reading-material/application-notes/miniaturization-rapid-processing-txtl-reactions-acoustic-liquid-handling
FOR RESEARCH USE ONLY. Not for use in diagnostic procedures
* Reaction costs converted from British pound sterling to US dollars based on the September 2020 exchange rate (1.28)
© 2020 Beckman Coulter, Inc. All rights reserved. Beckman Coulter, the stylized logo, and the Beckman Coulter product and service marks mentioned herein are trademarks or registered trademarks of Beckman Coulter, Inc. in the United States and other countries. ECHO is a trademark or registered trademark of Labcyte Inc. in the United States and other countries.