Safe Sample Prep - Rotors Level

Fixed-Angle-Ja 30 50 Ti  RotorEnhanced biosafety* for your lab users during centrifugation

Containment of biological agents and infectious substances is an essential element in maintaining a safe environment for biomedical and microbiological laboratories, Biosafety Levels labs, and vaccine production facilities.

  • A transparent design that enables you to check for broken labware
  • Protection from aerosol leakage and spills from rotor buckets
  • Biocontainment* that has been third-party tested
  • Bucket covers for 1.5 mL tubes to 750 mL bottles
  • Microplate carrier covers for 96-well plate format
The bio safety levels for Beckman Coulter Rotors
Bio Certified - BIO-C   Bio Enhanced - BIO-E   BioSafety
BioC (BioCertified)
BioCertified is a term used to describe our products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent, third-party facility (Health Protection Agency, Porton Down, UK). Improper use or maintenance may affect seal integrityand, thus, containment.
  BioE (BioEnhanced)
BioEnhanced is a term intended to describe our products’ enhanced level of biocontainment by design.
  BioSafety
BioSafe and BioSafety are terms intended to describe the enhanced biocontainment features of our products.

Rotor Features

Dual-locking Lids The dual-locking lid assembly allows the rotor to be loaded into and removed from the centrifuge with the lid attached. The rotor may be placed under a safety hood before the lid is attached or removed. The rotor is also available with a single-locking lid assembly.

Dual-Locking Lids provide sample containment by enabling the rotor to remain sealed while being transported to a biocontainment hood.

Hermetic Seal Lid and cap assemblies for fixed-angle and swinging-bucket rotors are designed to create a hermetic seal with the O-ring when used in a hard-vacuum environment. Also, for the ultracentrifuge swinging bucket rotors, they have racks that allow the buckets to be removed from the rotor body and filled with tubes under a biocontainment hood.

Fluid Containment Annulus Rotor has a fluid-containment annulus, located below the O-ring sealing surface. If tubes/bottles are overfilled or if leakage occurs during centrifugation, the annulus holds enough volume that all of the liquid is kept inside the rotor - even if all tubes leak at the same time. This feature virtually eliminates the escape of liquid into the centrifuge chamber.

Rotor Accessories for benchtop and high performance swinging bucket rotors, there are accessories that can be used that allow for biocontaiment.

  • Aerosolve Canisters
  • Bucket covers for 1.5 mL tubes to 750 mL bottles
  • Microplate carrier covers for 96-well plate format
  • Which all feature
    • A transparent design that enables you to check for broken labware
    • Protection from aerosol leakage and spills from rotor buckets
    • Ability for buckets to be loaded within a biocontainment hood

*BioSafe is a term intended to describe the enhanced BioSafety features of our products.

BioSafety Rotors from Beckman Coulter
High Performance | Table Top | Ultracentrifugation


High Performance BioSafety Rotors

JA-10.100

Get More Info

Max RPM 102,000
Capacity 6 x 100 mL
Max g 11,420 xg

JA-25.50

Get More Info

Max RPM 25,000
Capacity 8 x 50 mL
Max g 75,600 xg

JA-25.15

Get More Info

Max RPM 25,000
Capacity 360mL, 24 x 15mL
Max g 74,200 xg

JA-20.1

Get More Info

Max RPM 20,000
Capacity 32 x 15 mL
Max g 51,500 xg

JA-20

Get More Info

Max RPM 20,000
Capacity 8 x 50 mL
Max g 48,400 xg

JA-18

Get More Info

Max RPM 18,000
Capacity 10 x 100 mL
Max g 47,900 xg

JA-17

Get More Info

Max RPM 17,000
Capacity 14 x 50 mL
Max g 39,800 xg

J-LITE JLA 16.250

Get More Info

Max RPM 16,000
Capacity 1,500mL, 6 x 250mL
Max g 38,400 xg

JA-14

Get More Info

Max RPM 14,000
Capacity 6 x 250 mL
Max g 30,100 xg

JA-14.50

Get More Info

Max RPM 14,000
Capacity 16 x 50 mL
Max g 35,000 xg

JA-12

Get More Info

Max RPM 12,000
Capacity 600mL, 12 x 50mL
Max g 23,200 xg

JLA-10.500

Get More Info

Max RPM 10,000
Capacity 6 x 500 mL
Max g 18,600 xg

JLA-8.1000

Get More Info

Max RPM 8,000
Capacity 6 x 1,000 mL
Max g 15,970 xg

JLA-9.1000

Get More Info

Max RPM 9,000
Capacity 4 x 1,000 mL
Max g 16,800 xg

JS-5.3

Get More Info

Max RPM 5,300
Capacity 2L
Max g 68,700 xg

JS-5.2

Get More Info

Max RPM 5,200
Capacity 4L
Max g 6,840 xg

JS-4.2

Get More Info

Max RPM 4,200
Capacity 6L
Max g 5,020 xg

JS-4.3

Get More Info

Max RPM 4,300
Capacity 3L
Max g 4,220 xg

JS-4.0

Get More Info

Max RPM 4,000
Capacity 4L
Max g 4,050 xg

JS-4.750

Get More Info

Max RPM 4,750
Capacity 3L
Max g 5,250 xg

Table Top BioSafety Rotors

F12x8.2

Get More Info

Max RPM 14,000
Capacity 200µL
Max g 20,800 xg

F241.5

Get More Info

Max RPM 15,300
Capacity 24 x 2.0 mL
Max g 20,940 xg

F301.5

Get More Info

Max RPM 14,000
Capacity 400mL, 8 x 50mL
Max g 30 x 2.2 mL xg

F2402H

Get More Info

Max RPM 26,000
Capacity 24 x 2.0 mL
Max g 61,970 xg

H6002

Get More Info

Max RPM 122,000
Capacity 84 x 1.8 mL
Max g 12,400 xg

FA361.5

Get More Info

Max RPM 15,000
Capacity 36 1.5/2.0; mL 11.00 / 36 1.5/2.0; mL 0.43
Max g 20,124 xg

TA-15-1.5

Get More Info

Max RPM 15,000
Capacity 45.00|mL
Max g 25,160 xg

FX6100

Get More Info

Max RPM 10,200
Capacity 6 x 100 mL
Max g 11,400 xg

SX4400

Get More Info

Max RPM 4,700
Capacity 16,000mL
Max g 4,255 xg

SX241.5

Get More Info

Max RPM 14,000
Capacity 52.80|mL
Max g 16,220 xg

TS-5.1-1-500

Get More Info

Max RPM 5,100
Capacity 2L
Max g 5,530 xg

SX4750

Get More Info

Max RPM 4,750
Capacity 3L
Max g 5,250 xg

SX4750A

Get More Info

Max RPM 4,750
Capacity 3L
Max g 5,250 xg

PTS-2000

Get More Info

Max RPM 3,250
Capacity 4 80x10; mL
Max g 680 xg

Ultracentrifugation BioSafety Rotors

TLA-120.2

Get More Info

Max RPM 120,000
Capacity 20mL
Max g 627,200 xg

TLA-100

Get More Info

Max RPM 120,000
Capacity 40.8 mL
Max g 657,000 xg

TLA-55

Get More Info

Max RPM 35,000
Capacity 18mL
Max g 186,000 xg

TLS-55

Get More Info

Max RPM 55,000
Capacity 8.8mL
Max g 259,000 xg