Manufacturing Processes for Engineered T-Cell Therapy – CAR-T
Why T cells are important
- They recognize host vs. non-host cells to initiate an immune response
- They’re the primary immune system agents that attack diseased cells or infection
- They’re used in several cell-based therapies:
- Transplantation of donor T-cells - a bone marrow transplant, in which a matched donor’s cells are used to replace the patient’s cells, is the most widely used approach—typically for diseases that originate in the immune system (e.g., leukemia).
- Isolation and enrichment of a patient’s T-cells – an approach considered the safest because it enhances a patient’s own immune response to disease.
- CAR-T therapy – a more recent approach in which T-cells are removed, genetically engineered to express a synthetic receptor against specific cancer cells, then infused back into the patient’s bloodstream; this therapy is effective because many cancer cells “hide” from the immune system by appearing to be normal cells, thereby triggering no immune response.
Examples of parameters collected during cell therapy production
Data Collected |
Why and When |
Viable Cell Count | Used throughout process to monitor cell viability and impact of any cell manipulation events. |
Cell Size and Volume | Used as label-free method to monitor cell population during expansion, differentiation and/or transduction stages. Cell volume is a critical indicator of the activation state of the T-cells. |
Cell Count | General population monitor, particularly during expansion stages and when sample volume is manipulated (e.g., during concentration and packaging) |
Aggregate Detection | Primarily a concern during packaging and prior to administration |
Gene Expression | Looking for specific surface marker expression or reporter gene expression |
Metabolic Indicators | General monitoring during expansion stages when cells are under continuous culture |
Immunophenotyping | Critical to ensure correct cell types are isolated and enriched in therapy population; often used to define purity |
CAR-T Production Workflow
*The DART data manager captures data from devices integrated into a Biomek robotic workstation. The Vi-CELL BLU and CytoFLEX can both be optionally integrated to a Biomek to enable this data capture and association with a sample ID.
T-Cell Isolation
Output material generated in CAR-T cell manufacturing can be significantly affected by the starting raw materials. Leukapheresis is used to prepare/concentrate whole blood components (e.g., T-cells separated from red blood cells).
To maximize output of the CAR-T cell manufacturing process, samples are assessed for critical criteria, including:
- Cellular viability
- Change in cell volume
- Cell counts
- Rapid microbial testing
- Mycoplasma testing
- Immunophenotype
MULTISIZER 4e AND VI-CELL BLU ANALYZERS2
Defining conditions for cell viability and cellular proliferation are critical indicators of isolation conditions.
- Evaluate incoming samples
- Accurately analyze change in cell volume/size
- Rapidly determine cell count
- Supports 21 CFR Part 11 compliance
AVANTI J-26S XP HIGH-PERFORMANCE CENTRIFUGE FOR ELUTRIATION
The counterflow centrifugation elutriation system is a gentle, yet powerful technique for harvesting large populations of living cells, resulting in high viability rates.
- Collects/separates cells using the JE-5.0 elutriation rotor
- Lets users select chamber flow rate and centrifugal speed based on cell size
- Uses counterflow to separate based on density/size
- Pushes cells into flask for easy, high-yield collection
- Uses centrifugal force versus flow pump
BIOMEK i5 LIQUID HANDLER
Dispensing raw material inputs into unitized formats reduces manual manipulation steps, thereby reducing variability. Biomek iSeries workstations further reduce operator-induced variability by shuttling samples to integrated end-point analysis platforms (e.g., cell counters, flow cytometers).
- Start-to-end automation
- Innovative integration options
- Supports 21 CFR Part 11 compliance
CYTOFLEX FLOW CYTOMETER1
Integrated CytoFLEX flow cytometers can phenotype and quality check raw materials for the manufacturing process to ensure standardization of protocols.
- Immunophenotyping of cells to characterize target T-cell populations
- Supports 21 CFR Part 11 compliance
DURA INNOVATIONS1
Standardized dry antibody panels for comprehensive immunophenotypic characterization of source materials.
- Reduction of error-prone antibody pipetting
- Room temperature-stable unitized format, minimizing reagent inventory management
- Automation-friendly streamlined staining protocols
- GMP-compliant manufacturing
T-Cell Activation
T-cell activation and population expansion are critical for viral vector delivery and increased autologous dosage availability. Cell volume is a critical indicator of the activation state of the T-cell.
MULTISIZER 4 e COULTER SIZE ANALYZER2
Monitor:
- Cell volume change after activation to determine cell state
- Cell proliferation during expansion
VI-CELL BLU AND VI-CELL METAFLEX ANALYZERS2
- Viable cell count using trypan blue if required/desired
- Rapid metabolite analysis to monitor bioreactor health
GENE TRANSFER: VIRAL VECTOR DELIVERY
Transformation of endogenous T-cell populations that carry a diverse array of antigen receptors into a homogeneous population with a target-specific receptor is the hallmark of CAR-T cell technology.
The process for efficient viral vector delivery presents significant challenges when performed manually. Viral vector delivery for CAR is achieved in small doses and by incremental up-scaling to improve transduction efficiency. Furthermore, culture conditions must be continuously monitored for in-process control.
For example the culture media is routinely assessed for bioanalytes such as pH, pO2, pCO2, glucose, lactate, electrolytes and more.
BIOMEK i5 LIQUID HANDLER
- Start-to-end automation
- Innovative integration options
- Supports 21 CFR Part 11 compliance
MULTISIZER 4 e COULTER ANALYZER2
Monitor:
- Cell volume change after transduction with CAR vector
- Cell proliferation during expansion
VI-CELL METAFLEX2
- Rapid in-process control
- Rapid metabolite analysis to monitor bioreactor health
T-Cell Expansion
MULTISIZER 4e AND VI-CELL BLU ANALYZERS2
Defining conditions for cell viability and cellular proliferation are critical indicators of isolation conditions.
- Accurately analyze change in cell volume/size
- Rapidly determine cell count
- Supports 21 CFR Part 11 Compliance
BIOMEK i5 LIQUID HANDLER
Dispensing raw material inputs into unitized formats reduces manual manipulation steps, thereby reducing variability. Biomek iSeries workstations further reduce operator-induced variability by shuttling samples to integrated end-point analysis platforms (e.g., cell counters, flow cytometers).
- Start-to-end automation
- Innovative integration options
- Supports 21 CFR Part 11 compliance
CYTOFLEX FLOW CYTOMETER1
Integrated CytoFLEX flow cytometers can phenotype and quality check raw materials for the manufacturing process to ensure standardization of protocols.
- Immunophenotyping of cells to characterize target T-cell populations
- Supports 21 CFR Part 11 Compliance
DURA INNOVATIONS1
Standardized dry antibody panels and dry stimulation mixes for assessment of CAR T cell phenotype and function (e.g. IFNγ, TNFα, IL-2). • Reduction of error-prone antibody pipetting and laborious handling of stimulation mixes
- Room temperature-stable unitized format, minimizing reagent inventory management
- Automation-friendly synchronous staining of surface markers and cytokines in a single step
- GMP-compliant manufacturing
T-Cell Formulation
Upon efficient manufacturing and expansion of CAR-T cells, characterization of output material is required for generating a standardized, unitized packaged product. Automated data collection and analysis reduce user-introduced bias for optimized formulation conditions.
MULTISIZER 4e AND VI-CELL BLU ANALYZERS2
Defining conditions for cell viability and cellular proliferation are critical indicators of isolation conditions.
- Evaluate finished product for change in cell volume and size analysis
- Rapidly determine cell count
- Maintain 21 CFR Part 11 compliance
CYTOFLEX FLOW CYTOMETER1
- Determine gene expression level of CAR vector
- Measure cell surface markers to confirm the appropriate cell population
KALUZA SOFTWARE WITH LIS CONNECTIVITY AND DART SOFTWARE1
Kaluza analysis software is designed to simply, efficiently and quickly analyze multicolor flow cytometry data. It enables you to:
- Easily transmit plots, statistics and keywords to a Laboratory Information System (LIS)
- Load any FCS-compliant file through standard 3.1
- Perform real-time processing of multicolor files of up to 20 million events
- Kaluza offers features supporting GMP compliance
DART (Data Acquisition and Reporting Tool) is a software package that gathers data and synthesizes runtime information from Biomek log files to capture each manipulation of the sample during the course of the method. DART enables you to:
- Browse live and historical run data from any device using a networked internet browser
- Reduce manual data integration
- Leverage historical data on labware for enhanced method programming
- Seamlessly port data between Biomek methods and individual liquid handlers
- Generate data reports via MS Excel table and pivot views, and SQL views
- Integrate with your Laboratory Information Management System
AVANTI HIGH-PERFORMANCE CENTRIFUGES
- Pellet cells from large harvest/culture
- 1 L fixed-angle option (Avanti JXN-26 and JLA-8.1000)
- 2.25 L swinging-bucket option (Avanti J-HC and JS-5.0)
- Package cells into HarvestLine bottle liners
- Minimize risk of contamination
- Obtain higher yields
- Increase workflow efficiency
GMP Compliance Testing
ROUTINE ENVIRONMENTAL MONITORING FOR THE CLEANROOM ENVIRONMENT
- Industry’s first embedded secure data transfer for supporting 21 CFR Part 11 compliance
- Cleanroom classification and monitoring to ISO 14644-1 & -2 as required by EU and USA GMP
- Well-executed environmental monitoring program test controls in place for maintaining cleanrooms to GMP standards
- Reduced complexity of cleanroom implementation/monitoring via automation of the data collection/reporting process
ON-LINE RELEASE TESTING FOR WFI AND PW
Total Organic Carbon and Conductivity Analyzer
- Specifically designed to help demonstrate compliance to the pharmacopoeial requirements for TOC and conductivity for purified water (PW) and water for injection (WFI)
- Secure electronic records for on-line release testing straight from the box
Why work with Beckman Coulter Life Sciences?
Our application experts have surveyed the market, looked at existing workflows and integrated our solutions at customer sites around the world. Let us help you minimize your R&D requirements by leveraging our experience and our workflow solutions.
- Our products are designed to support GMP compliance.**
- We offer PROService, an internet-based application that uses a proprietary data pipeline to remotely connect to our systems in your labs to help maximize instrument uptime and service efficiency.
- We’re a Danaher company, with the Danaher Business System (DBS) at its core. DBS is a proven model for achieving success. It drives every aspect of our culture and performance. We use DBS to guide what we do, measure how well we execute, and create options for doing even better. Let us help you apply DBS to your lab.
Learn more about CAR-T solutions
**The CytoFLEX, MET ONE 3400, PAT700, Multisizer 4e, Vi-CELL XR, Vi-CELL MetaFLEX, and Kaluza are designed to support GMP compliance. Our Avanti JXN series centrifuges have enhanced data management which provides the capabilities to support customers’ GMP processes
1 For research use only. Not for diagnostic purposes. All other products identified are not for use in diagnostic procedures.
2 The Multisizer 4e, Vi-CELL XR, and Vi-CELL MetaFLEX are for Laboratory Use Only