A research system that delivers analytical excellence by coupling extraordinary sensitivity, resolution and dynamic range with high-speed data collection. Along with the unprecedented detection capabilities of the instrument, the Gallios includes easy-to-use software and automation to facilitate superior performance of multi-color flow cytometry assays.

Specifications

Platform Flow Analyser
Detection Forward scatter: Fourier design (up to 3 measurements of forward angle), Side scatter: independently-focused photodiode with electronic attenuation, Fluorescence: FL1-FL10
Optics/Laser Power Blue solid state diode (488 nm/22 mW), Red solid state diode (638 nm/25 mW), Violet solid state diode 561 nm, 40 mW, Yellow solid state diode 561 nm, 21.5 mW (25 µm spatially-separated beam spots)
Flow Cell 150 x 460 µm rectangular quartz gel coupled with 1.2 NA lens
Signal Processing Dynamic range: 20-bit date acquisition, 1,048,576-channel workstation resolution, Digital sampling rate: 40MHz, Digital accuracy: < 5% error
Software Gallios
Power Requirements 50/60 Hz, 100-240 VAC
Temperature Range 15.5°C - 32°C
Humidity Restrictions 30%-85% (non-condensing)
Regulatory Status RUO
Throughput 80 tubes/hour for 10,000 normal whole blood lymphocytes, Up to 88 tubes/hour at 10,000 events per second of concentrated beads
Installation Category II
Fluidics 10 L IsoFlow external heath container, 20 L Waste Container, 1.5 L Flow Cleaning Fluid Tank , 1.5 L Internal Sheath Tank
Weight 104 kg / 229.3 lb
Width 95.3 cm / 37.5 in
Depth 70.1 cm / 27.6 in
Height 61 cm / 24 in
UNSPSC 41116015

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.