BioSafe† Optima™ MAX-TL Tabletop Ultracentrifuge 120,000 rpm (with TLN-120 Rotor), 657,000 x g (with TLA-110 Rotor) for 50 Hz, 220/240 V; 60 Hz, 120V; 50/60 Hz, 100 V operation, CE/CSA/NRTL. Includes Optima™ MAX HEPA Filter Kit. †Biosafe is a term intended to describe the enhanced Biosafety features of our products.

Specifications

Max Speed 120,000 rpm
Max g-Force 657,000.00 x g
BioSafe Yes
Acceleration 10 acceleration profiles
Deceleration 11 deceleration profiles
Speed Control ± 50 rpm of set speed
Timed Run 99 min, 59 sec Continuous run, short run
Max Capacity Volume Range 0 x 40.8 mL
Refrigeration System Solid state (thermoelectric temperature control system with forced air; no coolant; no CFCs/ODCs)
Max Heat Dissipation 0.7 kW (2,400 BTU/hr)
Speed Display Actual rotor speed in 10 rpm increments (below 5,000 rpm) & 100 rpm increments (above 5,000 rpm)
Temperature Control ± 2 °C of set temperature
Drive Type Cooling Variable Frequency Induction Drive with rotor overspeed ID
Display Full-color LCD touch screen
Time (Actual Display) Indicates estimated run time remaining
Temperature Range(s) Set temperature range: 0 to 40°C in 1°C increments
Zonal Capability No
Installation Category II
VacuumPump Below 10 microns (1.34 Pa)
Weight 105 kg / 231.5 lb
Width 73.9 cm / 29.1 in
Depth 61.7 cm / 24.3 in
Height 345 cm / 135.8 in
Clearances 7.6 cm: side & rear
Max Noise Output < 47 dBa
Additional Information Operating Languages: English, French, Italian, German, Spanish, Japanese, Russian, Korean, and Chinese (Simplified)
Power Requirements 200-240 VAC , 50/60 Hz, 100-120 VAC

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.