Solve shared lab challenges with the JXN 30 Three-phase Centrifuge. With all the applications of a floor-standing centrifuge, the JXN-30 features a rotor speed of 30,000 RPM and RCF greater than 100,000 x g. It’s compatible with an expansive library of rotors, including fixed-angle and swinging bucket options. Three-phase filtration breaks sluice down into its component solids, liquids and gasses. Exceptional performance, improved BioSafety and advanced levels of networking can help you master daily lab challenges and achieve the throughput you need for shared labs, GMP environments and networked instruments. Includes data logging and real-time run graphing functionality. Via network or mobile device, the MobileFuge app adds the ability to access and monitor data remotely, manage permissions, address error handling and more. Stores up to 1,000 user-defined programs and up to 50 profiles.

Specifications

Platform Avanti
Max Speed 30,000 rpm
Max g-Force to 110,500.00 x g
BioSafe Yes
Acceleration 11 acceleration profiles
Deceleration 12 profiles
Speed Control ± 10 rpm from 10,001 - max, ±0.15%
Timed Run 1 min to 99 hrs, 59 mins
Max Capacity Volume Range 1 x 4 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 1.5 kW (5,120 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Time (Actual Display) Real-time run monitoring, time elapsed, time remaining, hold.
Temperature Range(s) -20° to +40° C
Rotor Chamber Diameter 51.3 cm / 20.2 in
Rotor ID Automatic
Zonal Capability Yes
Installation Category II
Environmental Conditions -20°C to 40°C in 1° increments
Humidity Restrictions 80% (non-condensing)
Material(s) Steel, Plastic
Finish Powder Coat Paint
Weight 310 kg / 683.4 lb
Width 71 cm / 28 in
Depth 86 cm / 33.9 in
Height 86 cm (141 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output 62 dBa
Power Requirements 220 VAC, 50 Hz
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.