The J-E centrifuge accommodates the comprehensive J-Series line of standard and biosafe certified rotors and labware for sample sizes from just a few microliters up-to 4 liters. For total versatility, select the AllSpin JS-5.3 high capacity swinging bucket rotor system, capable of processing up-to twenty-four 96-well microtiter plates and offers the flexibility of processing a variety of sample sizes in bottles from 4 x 500 mL to 96 x 17 mm tubes. The J-E centrifuge generates maximum speeds up to 21,000 RPM (53,300 x g) and offers the capacity of processing up-to 4 liters in under 10 minutes. The J-E's high torque switched reluctance (SR) direct drive achieves faster acceleration and deceleration with gentle precision that delivers the fastest separations in the shortest run times, performance unattainable by standard high-speed centrifuges. Using CFC-free refrigerants and a maintenance-free vacuum pump to partially remove friction-generating air molecules, the J-E offers better temperature control (-10° C - +40° C in 1° C increments), a more energy efficient system, lower heat output (< 6,900 BTUs) and quieter operation for a comfortable, productive work environment.

Specifications

Platform Avanti
BioSafe Yes
Acceleration 2 profiles, Maximum (full accleration to set speed) & Slow
Deceleration 3 profiles (max, slow & off (coast)
Speed Control ±|50.00|actual rotor speed, ±50 rpm of set speed
Timed Run 1 min to 99:59 hrs, Hold
Max Capacity Volume Range 1.00|4.00|L
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Temperature Control ± 2 ° C|°C of set temperature after equilibration
Temperature Range(s) 10°C - 40°C in 1 degree increments
Zonal Capability Yes
Installation Category II
Humidity Restrictions < 95% (non-condensing)
Material(s) Steel, Structural Foam
Finish Control panel finish: Silicone elastomer, Powder Coat Paint
Weight /
Width /
Depth /
Height 91.40|cm (152.4 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Power Requirements 208 VAC, 240 V, 50/60 Hz

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.