Accelerate sample processing with the maximum g-force in a high-speed centrifuge. The J30I BioSafe Centrifuge achieves the fastest separations possible in the shortest time, with high performance. Samples spend more time at full force and less time in the centrifuge. The swinging-bucket and fixed-angle rotors provide maximum separation forces over 100,000 x g at speeds up to 30,000 RPM. The acceleration and deceleration rates of the J-30I are unmatched. Maximum capacity is 4.0L. Includes a HEPA (high-efficiency particulate arrestance) filter kit, which makes this instrument BioSafe.

Specifications

Platform Avanti
Max Speed 30,000 rpm
Max g-Force 110,500.00 x g
BioSafe Bio-Enhanced
Acceleration 12 minutes
Deceleration 13 minutes
Speed Control ± 10 rpm of set speed or 0.15%, whichever is greater
Timed Run 1 minute-99 hours, 59 minutes; Hold or Ω 2t
Max Capacity Volume Range 1 x 4 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 2 kW (6,900 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Drive Type Cooling Air-cooled
User Defined Programs/Steps Up to 30 two-step programs
Temperature Range(s) From -20°C to 40°C in 1° increments
Rotor Chamber Diameter 40.6 cm / 16 in
Rotor ID Automatic
Friction Reduction System Yes
Zonal Capability Yes
Imbalance Tolerance ±
Installation Category II
Sterile Available
Environmental Conditions -20°C to 40°C in 1° increments
Humidity Restrictions < 95% non-condensing
Material(s) Steel, Structural Foam
Finish Powder Coat Paint
Weight 310 kg / 683.4 lb
Width 71 cm / 28 in
Depth 86 cm / 33.9 in
Height 86 cm (141 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output 57 dBa
Additional Information Bio-Certified
Power Requirements 200/208/240 V, 50/60 Hz
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.