Enhanced performance compared to similar high speed or super speed centrifuges. New rotors enable forces of over 110,000g. Features include a high-torque SR Drive for the fastest acceleration and deceleration possible with gentle precision, automatic rotor identification and imbalance safety check, CFC-free refrigerants, and a friction reduction system. Compatible with all Beckman Coulter J rotors. System offers the fastest separations in the shortest time. Swinging-bucket and fixed-angle rotors provide maximum separation forces beyond 100,000 x g at speeds up to 30,000 rpm. Your productivity is ensured by unmatched accel/decel rates and an easy run set-up. Your sample spends more time at full force and less time in the centrifuge. Operates at near-Ultracentrifuge forces at over 100,000 x g for fast protein separations in the Avanti J-30I and the JA-30.50, the highest g-force fixed-angle rotor available in a high-performance centrifuge. Subcellular organelles are effectively separated by rate zonal centrifugation with the JS-24.38, a 6 x 38 mL swinging-bucket rotor. High Throughput: Four-liter batch throughput for bacteria and cell membrane isolation using the JLA-9.1000 J-LITE rotor at 16,800 x g. DNA sample preparation in up to 10 microplates with the JS-5.9 Rotor. Exclusive SR Drive technology offers the fastest accel and decel times. Low heat output and low energy consumption in a high efficiency machine.

Specifications

Platform Avanti
Max Speed 30,000 rpm
Max g-Force 110,500.00 x g
BioSafe No
Acceleration Maximum, Slow or Timed (1-10 minutes, 0-500 rpm)
Deceleration Maximum, Slow, Timed (1-10 minutes from 500-0 rpm) or Off
Speed Control ± 10 rpm of set speed or 0.15%, whichever is greater
Timed Run 1 minute-99 hours, 59 minutes; Hold or Ω 2t
Max Capacity Volume Range 1 x 4 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 2 kW (6,900 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Drive Type Cooling SR Drive* / Air cooled
Time (Actual Display) Indicates run time remaining (timed run) or elapsed time (hold run)
Temperature Range(s) -20° to +40° C
Rotor Chamber Diameter 40.6 cm / 16 in
Rotor ID Automatic
Friction Reduction System Yes
Zonal Capability Yes
Imbalance Tolerance ±
Installation Category II
Environmental Conditions -20°C to 40°C in 1° increments
Humidity Restrictions < 95% (non-condensing)
Material(s) Steel, Structural Foam
Finish Powder Coat Paint
Weight 310 kg / 683.4 lb
Width 71 cm / 28 in
Depth 86 cm (102.0 cm with air direviter extending)
Height 86 cm (141 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output 57 dBa
Power Requirements 220/380 VAC, 50 Hz, 3 Phase
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.