This build of the HP-26 XP is wired for Japan power grids only. The HP-26 XPs are designed for high throughput and versatility. Teamed with the J-LITE JLA-8.1000 6-liter rotor, polycarbonate and polypropylene bottles and disposable HarvestLine system liners, the HP-26 XP centrifuges can process 6 liters in 10 minutes. These versatile systems can run our full line of high-performance rotors, including the JS-5.3 rotor with optional microplate carriers and adapters for conical tubes and bottles. Includes DNA sample capability at up to 24 microplates at a time. Maximum speed is 82,000 x g (26,000 RPM). Elutriation functionality sorts individual particles by size.

Specifications

Platform Avanti
Max Speed 26,000 rpm
Max g-Force to 82,000.00 x g
BioSafe No
Acceleration Maximum or Slow
Deceleration Maximum, slow, or off
Speed Control ± 10 rpm from 10,000 - 26,000 or equivalent RCF
Timed Run 1 min to 99 hr 59 min; 2t or Continuous (hold)
Max Capacity Volume Range 1 x 6 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 2 kW (6,900 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Drive Type Cooling SR Drive* / Air cooled
Temperature Range(s) 10°C - 40°C in 1 degree increments
Rotor Chamber Diameter 51.3 cm / 20.2 in
Zonal Capability No
Installation Category II
Sterile Available
Humidity Restrictions < 95% (non-condensing)
Finish Powder Coat Paint
Weight 290 kg / 639.3 lb
Width 71 cm / 28 in
Depth 86 cm (102.0 cm with air direviter extending)
Height 86 cm / 33.9 in
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output 57 dBa
Additional Information Sterile available
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.