The J-26 XPI centrifuge brings standard-setting performance needed in a lab shared with multiple techs with varying processes, including high speed, low heat output, imbalance tolerance and low noise. The J26 XPI has upgraded accel/decel profiles from the J26 XP, from 2/3 to 12/13. Above and beyond its BioSafety systems, this centrifuge has a more impact-resistant lid, full containment barrier and automatic rotor identification. Its ergonomic design--with lower instrument height and hands-free door operation--remains unchanged. The J-265 XPI can process six liters of fermentor output in less than 10 minutes, deliver a subcellular fraction at 82,000 x g and run 24 microplates at a time. It automatically detects which rotor is installed and prevents the rotor from running above its maximum-rated speed, and enables quicker, quieter, more energy-efficient runs with enhanced temperature control. The exclusive high-torque, switched reluctance (SR) drive shortens cycle times.

Specifications

Platform Avanti
Max Speed 26,000 rpm
Max g-Force to 82,000.00 x g
BioSafe No
Acceleration Maximum, Slow or Timed (1-10 minutes, 0-500 rpm)
Deceleration Maximum, Slow, Timed (1-10 minutes from 500-0 rpm) or Off
Speed Control ± 10 rpm of set speed or 0.1%, whichever is greater
Timed Run 1 minute-99 hours, 59 minutes or Continuous Hold
Max Capacity Volume Range 1 x 6 L
Refrigeration System Non-CFC, non-ozone depleting refrigerant
Software Virtual Network Computing (VNC), Mobile Fuge app for Apple iOS and Android
Max Heat Dissipation 2 kW (6,900 BTU/hr)
Temperature Control ± 2 °C of set temperature after equilibration
Drive Type Cooling SR Drive* / Air cooled
Time (Actual Display) Indicates estimated run time remaining (timed run), 2t, or elapsed time (hold run)
Temperature Range(s) 10°C - 40°C in 1 degree increments
Rotor Chamber Diameter 51.3 cm / 20.2 in
Rotor ID Automatic
Friction Reduction System Mechanical rotary vane pump reduces chamber pressure to 0.25 ATM (190 mm Hg)
Zonal Capability Yes
Installation Category II
Sterile Available
Environmental Conditions -10°C to 40°C in 1° increments
Humidity Restrictions < 95% (non-condensing)
Material(s) Steel, Plastic
Finish Powder Coat Paint
Weight 290 kg / 639.3 lb
Width 71 cm / 28 in
Depth 86 cm (102.0 cm with air direviter extending)
Height 86 cm (149 cm with door open)
Clearances 7.6 cm (sides) & 16 cm (rear)
Pollution Degree 2
Max Noise Output 57 dBa
Additional Information Sterile available
UNSPSC 41103905

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.