A compact multipurpose benchtop variant of the Allegra X-30 centrifuge versatile enough for a general research setting or for clinical sample preparation. Provides excellent performance and easy operation in a compact design that saves time and laboratory space. Easy to use, the Allegra X-30 offers the highest speed and g-force in its class, with an extensive rotor library for multiple applications, a compact design at only 18 inches/46cm wide, a BioCertified* swinging-bucket and fixed-angle rotors. Three spin options for 1.5 mL PCR Tubes: Biocertified* 24-place fixed-angle rotor (29,756 x g); 30-place Fixed-angle Rotor (28,672 x g); and 24-place swinging-bucket rotor (16,244 x g) for flat pelleting. One rotor spins 500L to 1.6 mL. 4 x 400 mL with a maximum capacity of 4,700 rpm (4,255 x g) maximum g-Force. Includes 20 different adapters. Spins the following labware: 400 mL bottles, 250 mL bottles, 100 mL, 94 mL, 85 mL bottles, 50 mL conical and round-bottom tubes, 15 mL conical and round-bottom tubes, 30 mL, 10 mL tubes, 25 mL glass tubes, 5mL round-bottom tubes, 7 mL glass tubes, and 1.5 mL and 500 L PCR tubes *BioCertified is a term used to describe products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and containment.

Specifications

Platform Allegra 21
Max Speed 16,000 rpm with Fixed-Angle rotor (3,398 rpm with Swinging-Bucket rotor)
Max g-Force 23,511 (Fixed-Angle) 4,200 (Swinging Bucket) x g
Acceleration 10 acceleration profiles
Deceleration 10 deceleration profiles
Speed Control ± 50 rpm of set speed
Timed Run To 9 hrs 59 mins or Continuous run (8)
Max Capacity Volume Range 4 x 400 mL
Refrigeration System No
Regulatory Status IVD
Max Heat Dissipation 0.5 kW (1,638 BTU/hr)
Speed Display Actual rotor speed in 100 rpm increments or in RCF (when selected)
Drive Type Cooling Brushless Induction
Temperature Range(s) Ambient temperature range: +4° to +35°C
Friction Reduction System Asynchronous 3-phase Direct Drive
Installation Category II
Weight 48 kg / 105.8 lb
Width 46 cm / 18.1 in
Depth 55 cm / 21.7 in
Height 35.5 cm / 14 in
Max Noise Output <= 68 dBa
Power Requirements 50/60 Hz, 220-240 VAC
UNSPSC 41103900

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.