X-30R refrigerated model cools from room temperature to 4° C in fewer than ten minutes and has an operating temperature range of 2° C to 40° C (35° F to 104° F). The X-30R provides excellent performance and easy operation in a compact design that saves valuable time and laboratory space with the highest speed and g-force in its class (1.6L max capacity, 18,000 RPM, 29,756 x g). Simple and quick run setup. Versatile, with an extensive rotor library for multiple applications, plus a compact Design of only 18" wide (46cm). Includes a BioCertified* swinging-bucket and fixed-angle rotors. Rotor details: Three ways to spin the 1.5 mL PCR Tubes; Biocertified* 24-place fixed-angle rotor - 29,756 x g; 30-place fixed-angle rotor - 28,672 x g; 24-place swinging-bucket rotor - 16,244 x g for flat pelleting. One rotor spins 500 μL to 1.6 L; 4 x 400 mL - maximum capacity; 4,700 rpm - 4,255 x g - maximum g-force; 20 adapters. Spins the following labware: 400 mL bottles; 250 mL bottles; 100 mL, 94 mL, 85 mL bottles; 50 mL conical and round-bottom tubes; 15 mL conical and round-bottom tubes; 30 mL, 25 mL, 10 mL tubes; 1.5 mL and 500 μL PCR tubes. *BioCertified is a term used to describe products tested and validated to demonstrate containment of microbiological aerosols by an independent, third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and, thus, containment.

Specifications

Platform Allegra 21
Max Speed 18,000 rpm with Fixed-Angle rotor (4,700 rpm with Swinging-Bucket rotor)
Max g-Force 29,756 (Fixed-Angle) 4,255 (Swinging Bucket) x g
Acceleration 10 acceleration profiles
Deceleration 10 deceleration profiles
Speed Control ± 50 rpm of set speed
Timed Run To 9 hrs 59 mins or Continuous run (8)
Max Capacity Volume Range 4 x 400 mL
Refrigeration System Yes, CFC-Free
Max Heat Dissipation 1 kW (3,311 BTU/hr)
Speed Display Actual rotor speed in 100 rpm increments or in RCF (when selected)
Drive Type Cooling Brushless Induction
Temperature Range(s) From -20°C to 40°C in 1° increments
Friction Reduction System Asynchronous 3-phase Direct Drive
Installation Category II
Weight 78 kg / 172 lb
Width 46 cm / 18.1 in
Depth 70.7 cm / 27.8 in
Height 37 cm / 14.6 in
Max Noise Output <= 68 dBa
Power Requirements 60 Hz, 120 VAC
UNSPSC 41103904

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.