Spinning up to three liters of sample at an incredible 4,740 RPM / 5,250 x g, the refrigerated X-15R allows you to perform faster separations and optimized recoveries. The robust refrigeration cools from ambient to 4° C in less than 4 minutes – over 10 minutes faster than equivalent three liter centrifuges. Features include a pulse timer up to 99 hours and 59 minutes, ten user-defined programs with 10 acceleration and 11 deceleration profiles, and fast and slow blood component spins.

Specifications

Platform Allegra X-15
Max Speed 10,200 rpm with Fixed-Angle rotor (4,750 rpm with Swinging-Bucket rotor)
Max g-Force 11,400 (Fixed-Angle) 5,250 (Swinging Bucket) x g
Acceleration 10 acceleration rates
Deceleration 11 deceleration rates
Timed Run To 99 hrs 59 mins or continuous (hold)
Max Capacity Volume Range x 3000 mL
Refrigeration System Yes, CFC-Free
Max Heat Dissipation 2 kW (6,800 BTU/hr)
Speed Display Actual rotor speed in 10 rpm increments or in RCF (when selected)
Temperature Control ± 2.0 °C of set temperature
Drive Type Cooling Brushless Induction
User Defined Programs/Steps 10
Temperature Range(s) From -10°C to +40°C in 1° increments
Installation Category II
Humidity Restrictions < 75% (non-condensing)
Weight 128 kg / 282.2 lb
Width 76.2 cm / 30 in
Depth 62.2 cm / 24.5 in
Height 34.3 cm / 13.5 in
Clearances 7.6 cm: side & rear
Max Noise Output <= 68 dBa
Power Requirements 60 Hz, 208 VAC
UNSPSC 41103904

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.