Refrigeration unit added to the X-14 Benchtop Centrifuge. Temperature control from 2 - 40° C. Ambient temperature is 10 - 30° C. Refrigeration is CFC-free. Holds up to 10 user-defined programs. The Allegra X-14 benchtop centrifuge is a convenient, reliable workhorse piece of equipment that will speed up your process, cycle after cycle. The X-14 offers BioCertified* features for security from contamination, the ARIES Smart Balance Rotor System for faster setup and run times, and a versatile rotor for accommodating tubes, bottles and microplates. The X-14 has a maximum capacity of 3 L, offers extensive biocontainment options, and a 4 x 750 mL swinging bucket rotor (up to 4 300 x g/4300 rpm). Cell Culture Packages also include 15 mL (set of four) and 50 mL (set of four) conical adapters. Maximum capacity for these adapters is 56x15 mL and 28x50 mL. Blood Sample Preparation Application Packages also include 13 mm (set of four) and 16 mm (set of four) diameter tubes. Maximum capacity is 120x13 mm and 76x16 mm blood tubes per run. BioSafe Aerosolve Canister Packages also include a set of four Aerosolve canisters, four 15 mL conical tube rack, and four 50 mL conical tube racks. Maximum rack capacities are 24x15 mL and 16x50 mL. Microplate Application Packages hold up to sixteen standard microplates or four deep well plates. *BioCertified is a term used to describe products which have been tested and validated to demonstrate containment of microbiological aerosols by an independent third-party facility (Health Protection Agency, Porton Down, UK or USAMRIID, Ft. Detrick, MD, USA). Improper use or maintenance may affect seal integrity and containment.

Specifications

Max Speed 10,200 rpm with Fixed-Angle rotor (4,300 rpm with Swinging-Bucket rotor)
Max g-Force 11,400 (Fixed Angle) 4,303 (Swinging Bucket) x g
Acceleration 10 acceleration rates
Deceleration 11 deceleration rates
Timed Run To 99 hrs 59 mins or Continuous run (hold)
Max Capacity Volume Range x 3000 mL
Refrigeration System CFC-Free
Max Heat Dissipation 1.3 kW (4,318 BTU/hr)
Speed Display Actual rotor speed in 10 rpm increments or in RCF (when selected)
Temperature Control ± 2 °C of set temperature
Drive Type Cooling Brushless Induction
Time (Actual Display) Indicates estimated run time remaining
Temperature Range(s) 2° C to +40°C in 1° increments
Installation Category II
Humidity Restrictions < 75% (non-condensing)
Weight 128 kg / 282.2 lb
Width 76.2 cm / 30 in
Depth 62.2 cm / 24.5 in
Height 34.3 cm / 13.5 in
Clearances 7.6 cm: side & rear
Max Noise Output < 64 dBa
Power Requirements 120 V, 60 Hz

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.