Streamlined, simplified separations. Whether harvesting cells or separating blood components, the Allegra X-12R will simplify your processes and save you time. Offers a maximum capacity of 4 x 750 mL. Perfect for clearing debris, isolating mononuclear cells and pelleting mammalian cells. Uses CFC-free refrigerant with a range of –10° to 40° C. Maximum speed/RCF is 3,750 RPM / 3,270 x g. The Allegra X-12R lets you skip steps in cell culturing with cell lines, primary cells, adherent cells and suspension cells. Save time and labor while avoiding potential contamination step. Additional benefits include eliminating 15 mL or 50 mL conical tubes and centrifuging cells directly in T-75 cm2 or T-25 cm2 flasks. Complete your run, even with imbalance, thanks to the ARIES Smart Balance Rotor, which automatically corrects for imbalance up to 50 grams of opposing loads. Adapters currently available for Corning T-75 cm2 or T-25 cm2 canted-neck cell culture flasks. Numerical keypad controls and programmable with up to ten user-defined programs.

Specifications

Platform Allegra X-12
Max Speed 10,200 rpm with Fixed-Angle rotor (3,750 rpm with Swinging-Bucket rotor)
Max g-Force 11,400 (Fixed Angle) 3,270 (Swinging Bucket) x g
Acceleration 10 acceleration rates
Deceleration 11 deceleration rates
Timed Run To 99 hrs 59 mins or continuous (hold)
Max Capacity Volume Range x 3000 mL
Refrigeration System CFC-Free
Max Heat Dissipation 1.2 kW (4,100 BTU/hr)
Speed Display Actual rotor speed in 10 rpm increments
Temperature Control ± 2 °C of set temperature
Drive Type Cooling Brushless Induction
Time (Actual Display) Indicates estimated run time remaining
Temperature Range(s) From -10°C to +40°C in 1° increments
Installation Category II
Humidity Restrictions < 75% (non-condensing)
Material(s) Coated polystyrene copolymer, Acrylic baking enamel
Weight 121 kg / 266.8 lb
Width 197 cm / 77.6 in
Depth 62.2 cm / 24.5 in
Height 173 cm / 68.1 in
Clearances 7.6 cm: side & rear
Max Noise Output < 68 dBa
Power Requirements 208 VAC, 60 Hz
UNSPSC 41103904

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.