Features dual integrated optical systems that include Rayleigh Interference optics and scanning UV/Visible optics. The Rayleigh Interference system extends the working concentration range of the analytical ultracentrifuge, and is ideal for samples that do not absorb in the UV/Visible range such as polysaccharides, carbohydrates, and polymers. The Windows User Interface and Data Analysis Software, included with each ProteomeLab XL-I, interprets the data to provide information about association states of interacting molecules, association constants, weight average molecular weight, sedimentation and diffusion coefficients and conformation changes. The XL-1 runs up to 21 samples using the appropriate cell assemblies and rotor. Basic hands-on instrument and software training is provided with the purchase of a ProteomeLab. System includes an-50 Ti 8-hole rotor, 3 assembled cells (flow through centerpiece, quartz windows), counterbalance set, torque stand and an accessory kit that includes a start-up kit.

Specifications

Platform Analytical
Max Speed 50,000 rpm
Max g-Force 289,848.00 x g
Acceleration 5-400 rpm/second (above 500 rpm), 400 max acceleration
Deceleration 5-400 rpm/second (above 500 rpm), 400 (max deceleration)
Speed Control ±20 rpm of set speed (above 1,000 rpm)
Timed Run 1 to 999 hrs, 59 mins (including hold runs)
Max Capacity Volume Range 0 x 0.4 mL
Operating System(s) LINUX
Software XP Professional
Max Heat Dissipation 1 kW
Speed Display 1,000 to rated speed in 100 rpm increments
Temperature Control 0.50 °C of set temperature after equilibration
Time (Actual Display) Real-time run monitoring, time elapsed or time remaining (hold run)
Temperature Range(s) Set temperature range: 0 to 40°C in 1°C increments, Rotor temperature after equilibration: ±0.5°C of set temperature, Displayed rotor temperature after equilibration: ±0.3°C of set temperature
Zonal Capability No
VacuumPump Below 5 microns (0.7 Pa)
Humidity Restrictions < 95% non-condensing
Finish Top surface finish: Urethane paint, Metal surfaces: Acrylic baking enamel , Control panel finish: Coated polycarbonate
Weight 465 kg / 1025.1 lb
Width 94 cm / 37 in
Depth 67.3 cm / 26.5 in
Height 120.7 cm / 47.5 in
Clearances 5.1 cm (sides) & 15.2 cm (rear)
Pollution Degree 2
Max Noise Output < 57 dBa
Power Requirements 200-240 VAC , 50/60 Hz, 20 A, IBM computer: 100-120 VAC, 60 Hz, or 220-240 VAC, 50 Hz
UNSPSC 41103900

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.