The Optima AUC (A) An-60 Ti Bundle is the base analytical ultracentrifuge with 300 Hz, 10 µJM Xenon Flash Absorbance optics and also includes a 4-hole An-60 Ti analytical rotor, analytical cell, torque stand, counterbalance kit, accessory kit, and cell housing kit.

Specifications

Platform Optima AUC
Max Speed 60,000 rpm
Max g-Force 289,848.00 x g
Acceleration 5-400 rpm/second (above 500 rpm), 400 max acceleration
Deceleration Maximum, Slow & Off
Speed Control ± actual rotor speed, ± 2 rpm at steady state
Timed Run 1 to 999 hrs, 59 mins (including hold runs)
Max Capacity Volume Range 0 x 0.4 mL
Operating System(s) LINUX
Software Experimental portal can be ran on MS IE 10 (or above); Safari 8 (or above); Chrome 42 (or above)
Max Heat Dissipation 1 kW
Speed Display 1,000 to rated speed in 100 rpm increments
Temperature Control 0.50 °C of set temperature after equilibration
Display 15.3" high-resolution color touch screen
Time (Actual Display) Real-time run monitoring, time elapsed or time remaining (hold run)
Temperature Range(s) Ambient temperature range: 10 to 30°C, Set temp: 7-40° C (1°C increments at > 25-30°C ambient temp); 4-40°C (1°C increments at <25°C ambient temp)
Operating Mode(s) LINUX for remote monitoring; GUI (any OS)
Zonal Capability No
Sterile No
VacuumPump Below 5 microns (0.7 Pa)
Humidity Restrictions <80% at <30°C (non-condensing)
Finish Rotor pad: Coated polycarbonate, Top & front surfaces: Polyurethane, Other surfaces: Kydex plastic & polyurethane painted aluminum
Weight 508.5 kg / 1121.1 lb
Width 94 cm / 37 in
Depth 68.1 cm / 26.8 in
Height 125.7 cm / 49.5 in
Clearances 5.1 cm (sides) & 15.2 cm (rear)
Pollution Degree 2
Max Noise Output <60dBa
Additional Information Computer not included in system configuration. 100% of content is ROHS compliant material.
Power Requirements 30 A branch circuit, 50/60 Hz, 200-240 VAC
UNSPSC 41103907

NOT ALL PRODUCTS ARE AVAILABLE IN ALL COUNTRIES
PRODUCT AVAILABILITY AND REGULATORY STATUS DEPENDS ON COUNTRY REGISTRATION PER APPLICABLE REGULATIONS

The listed regulatory status for products correspond to one of the below:
IVD: In Vitro Diagnostic Products. These products are labeled "For In Vitro Diagnostic Use."
ASR: Analyte Specific Reagents. These reagents are labeled "Analyte Specific Reagents. Analytical and performance characteristics are not established."
CE: Products intended for in vitro diagnostic use and conforming to European Directive (98/79/EC). (Note: Devices may be CE marked to other directives than (98/79/EC)
RUO: Research Use Only. These products are labeled "For Research Use Only. Not for use in diagnostic procedures."
LUO: Laboratory Use Only. These products are labeled "For Laboratory Use Only."
No Regulatory Status: Non-Medical Device or non-regulated articles. Not for use in diagnostic or therapeutic procedures.