Sigma's Automated Protocol for Extract-N-Amp* Plant PCR* Kits on
the Biomek® FX Sigma-Aldrich Corporation – www.sigmaaldrich.com
Product Components
Reagents Provided |
Product Code |
Extract-N-Amp Plant XNAR |
REDExtract-N-Amp Plant XNAPR |
SYBR Green Extract-N-Amp Plant XNAPRG |
| |
Package Size |
1,000 extractions 1,000 amplifications |
1,000 extractions 1,000 amplifications |
1,000 extractions 1,000 amplifications |
Extraction Solution |
E7526 |
120 ml |
120 ml |
120 ml |
Dilution Solution |
D5688 |
120 ml |
120 ml |
120 ml |
| Extract-N-Amp PCR Ready Mix or SYBR Green Extract-N-Amp PCR Ready Mix |
E3004 (for XNAR) R4775 (for XNAPR) S4320 (for XNAPRG) |
12 ml |
12 ml |
12 ml |
The Extract-N-Amp Plant PCR Kits can be stored at 2-8 °C for up to 3 weeks.
For long-term storage, store at –20 °C. Do not store in a frost-free freezer.
Materials to be Supplied by the User
Source |
Part No. |
Quantity |
Description |
| Sigma-Aldrich |
G2N10, G2N70, and G2N250 |
1 |
(Optional) GenElute* Plant Genomic DNA Miniprep Kit for use as genomic
DNA control |
| Sigma-Aldrich |
W4502 |
1 |
Water, molecular biology reagent |
| Sigma-Aldrich |
P4616 |
1 |
96-well PCR plates, with full skirt |
| ABgene |
AB-1100 |
1 |
96-well PCR plates, with half skirt |
| Fisher |
07200694 |
1 |
Lid, universal |
| ABgene |
AB-0866 |
1 |
Ultra clear cap strip |
| Corning |
6525 |
1 |
Corning plate holder |
| Sigma-Aldrich |
Z369659 |
1 |
Sealing film, SealPlate |
| Fisher |
05-405-22 |
1 |
24-position Eppendorf* IsoTherm System |
| Innovative Microplates |
S30028 |
1 |
12-column reagent reservoir with low profile |
| Innovative Microplates |
S30018 |
1 |
96-well reservoir with low profile and pyramidal bottom |
| Innovative Microplates |
S30019 |
1 |
(Optional) 12-column reagent reservoir with high profile |
| Innovative Microplates |
S30014 |
1 |
(Optional) 96-well reservoir with high profile and pyramidal bottom |
| Fisher |
15-077-26 |
1 |
Thermometer |
| Customer Supplied |
N/A |
1 |
Plant leaf tissues |
| Customer Supplied |
N/A |
1 |
Paper punch (standard one-hole) |
| Customer Supplied |
N/A |
1 |
Forceps (small to medium in size) |
| Customer Supplied |
N/A |
1 |
Microcentrifuge tubes (1.5 ml, 2 ml screw cap) |
| Customer Supplied |
N/A |
1 |
Thermal Cycler |
Instrument Requirements for the Biomek FX Workstation
Source |
Part No. |
Quantity |
Description |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Orbital Shaker |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Peltier ALP |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Multichannel Pod (96 Mandrel 200 µl Head) |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Span-8 Pod (1 ml Syringe) |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Gripper |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Tip Loader |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Span-8 Tip Trash |
| Beckman Coulter, Inc. |
Beckman Coulter |
1 |
Span-8 Tip Trash |
| Beckman Coulter, Inc. |
Beckman Coulter |
4 |
Standard Passive ALPs (One by Three) |
| Beckman Coulter, Inc. |
Beckman Coulter |
3 |
Standard Passive ALPs (One by One) |
| Beckman Coulter, Inc. |
717253 |
2 |
AP96 P250 Barrier Tips, Sterile |
| Beckman Coulter, Inc. |
717256 |
1 |
AP96 P20 Barrier Tips, Sterile |
| Beckman Coulter, Inc. |
379503 |
1 |
Span-8 P250 Barrier Tips, Sterile |
| Beckman Coulter, Inc. |
379506 |
1 |
Span-8 P20 Barrier Tips, Sterile |
* All trademarks are the property of their respective owners. Where applicable,
the PCR process is covered by patents owned by Roche Molecular Systems,
Inc., and F. Hoffman-LaRoche, Ltd.
eLabNotebook
Sitemap |