Promega's MagneSil* ONE, Fixed Yield Blood Genomic System
on the Biomek® FX
Promega Corporation – www.promega.com
Product Components
MagneSil* ONE, Fixed Yield Blood Genomic System, 1 × 96 preps, Part
No. MD1370
For Laboratory Use. Each system contains sufficient reagents to perform
approximately, 1 × 96-well plate preparation. The MagneSil* ONE,
Fixed Yield Blood Genomic System includes:
• 160 ml Lysis Buffer, Blood
• 25 ml MagneSil* PMPs - Fixed Yield
• 120 ml Alcohol Wash, Blood
• 45 ml Elution Buffer, Blood
• 300 µl Anti-Foam Reagent
• 1 Protocol
Storage Conditions: All components should be stored at room temperature
(20–25°C). Do not freeze the MagneSil* PMPs.
Materials to Be Supplied by the User
| Source |
Part No. |
Quantity |
Description |
| Promega Corporation |
V3031 |
1 |
Deep Well MagnaBot* 96 Magnetic Separation Device |
| Promega Corporation |
V8581 |
1 |
MagnaBot* Spacer, 1/8 Inch |
| Marsh |
AB-0932 [2.2ml] and AB-0787
[1.2ml] or comparable |
1 |
Deep-well microwell plates |
| Innovative Microplates |
S30014 |
1 |
Pyramid bottom 96-well reservoirs |
| Promega Corporation |
Z3271 |
1 |
Heat Transfer Block |
| Promega Corporation |
A9161 |
1 |
96-Well Collection Plate |
Biomek® FX Equipment
| Source |
Part No. |
Quantity |
Description |
| Beckman Coulter, Inc. |
267689 |
1 |
Biomek FX Software |
| Beckman Coulter, Inc. |
719368 |
1 |
96-channel Pod |
| Beckman Coulter, Inc. |
719357 |
16 |
Minimum number of Labware positions by
1 Pod |
| Beckman Coulter, Inc. |
719356 |
1 |
Tip Loader ALP |
| Beckman Coulter, Inc. |
719361 |
1 |
Heating/Cooling ALP, Single Position |
| Beckman Coulter, Inc. |
379448 |
1 |
Orbital Shaker ALP (optional) |
| Beckman Coulter, Inc. |
719363 |
1 |
Tip Wash Station (96-channel)(optional) |
| VWR International |
13272-200 |
1 |
Recirculating Waterbath |
Consumables
| Source |
Part No. |
Quantity |
Description |
| Promega Corporation |
V3031 |
1 |
Deep Well MagnaBot® 96 Magnetic Separation Device |
| Promega Corporation |
V8581 |
1 |
MagnaBot* Spacer, 1/8 Inch |
| Promega Corporation |
Z3271 |
1 |
Heat Transfer Block |
| Marsh |
AB-0932 |
2 |
2 ml Deepwell plates (or comparable) |
| Marsh |
AB-0564/BP |
1 |
1.2 ml Deepwell plates (or comparable) |
| Innovative Microplate |
S30014 |
1 |
Pyramid-bottom 96-well reservoir
(or comparable) |
| Greiner America |
650101 |
2 |
Polystyrene U-bottom multiwell plate (or comparable) |
| Beckman Coulter, Inc. |
717253 |
3 |
Biomek AP96 P250 tips, sterile barrier |
* All trademarks are the property of their respective owners. Where applicable,
the PCR process is covered by patents owned by Roche Molecular Systems,
Inc., and F. Hoffman-LaRoche, Ltd.