eLabNotebook > Nucleic Acid Prep & Purification > Plasmid DNA Purification > Promega Cells to Gels
MagneSil* Biomek® FX


Promega's Cells to Gels MagneSil* Plasmid Purification Protocol on the Biomek® FX

Promega Corporation – www.promega.com

Product Components
ProductSizeCat.#
Wizard* MagneSil* Plasmid Purification System4 × 96A1630
8 × 96A1631
Wizard* MagneSil* Plasmid Purification System, HTP1100 × 96A1635


Cat.# A1630 includes sufficient reagents for a minimum of 4 × 96 well plates. Includes:

• 50ml Cell Resuspension Solution
• 60ml Cell Lysis Solution
• 60ml Neutralization Solution
• 19ml MagneSil* BLUE
• 30ml MagneSil* RED
• 50ml Elution Buffer
• 16 Collection Plates
• 1 Protocol


Available Separately
ProductSizeCat.#
MagneSil* BLUE100mlA2201
MagneSil* RED100mlA1641
Cell Resuspension Solution500mlA7114
Cell Lysis Solution500mlA7132
Neutralization Solution500mlA7132
Elution Buffer500mlA1655

Materials to Be Supplied by the User

• 96-well, U-bottom plates (Greiner Cat.# 650101)
• Innovative Microplate reagent reservoirs
(Innovative Microplate Cat.# S30014)
• V-bottom, deep-well culture plates (Fisher Cat.# 07-200-700, Costar Cat.# 3960)
• 80% ethanol
• 100% isopropanol
• 5M NaCl

Many types of reservoir and deep-well culture plates are available. However, the MagnaBot* 96 Magnetic Separation Device is specifically designed for use with Greiner U-bottom microplates. Optional lids are available for Innovative Microplate reservoirs (Innovative Microplate Cat.# A50014)

Instrument requirements for the Biomek® FX Workstation

Source Part No. Quantity Description
Beckman Coulter, Inc.
267689
1
Minimum: Biomek® FX Software version 2.1
Beckman Coulter, Inc.
719368
1
96-channel POD
Beckman Coulter, Inc.
719357
10
Minimum number of Labware Positions by 1 POD
Beckman Coulter, Inc.
719356
1
Tip Loader
Beckman Coulter, Inc. 717251
3
Biomek® AP96 P250 Tips, Nonsterile
Beckman Coulter, Inc. 719363
1
Biomek® FX Disposable Tip Wash ALP
Beckman Coulter, Inc. 719804
3
Biomek® FX Single Position ALP with Indented Sides
Beckman Coulter, Inc. 719360
1
High Density 16-Position ALP
Beckman Coulter, Inc. 719361
1
Biomek® FX Heating/Cooling ALP
Beckman Coulter, Inc. 379410
1
Orbital Shaker
Beckman Coulter, Inc. 719366
1
Biomek® FX Device Controller
Additional Intrument Requirements
 
1
Circulating water bath capable of 65°C
(for the Heating/Cooling ALP)
Promega Corporation V8151
1
MagnaBot* 96 Magnetic Separation Device
Promega Corporation V8381
1
MagnaBot* Spacer
Promega Corporation Z3271
1
Heat Transfer Block

Storage Conditions: Store all components at 22–25°C.

* All trademarks are the property of their respective owners. Where applicable, the PCR process is covered by patents owned by Roche Molecular Systems, Inc., and F. Hoffman-LaRoche, Ltd.

eLabNotebook Sitemap

©1998 - 2006 Beckman Coulter, Inc.