Liquid Handling Volume Range
Pipetting Module (5 μL to 1,000 μL)
Syringe Pump Size
Aspiration/Dispense pump 2mL
Wash/Prime pump 5 mL
IMMUNOPREP™ reagents A, B, C 2 mL
Flow-Count™ pump 2 mL
Specimen Size 5 μL to 1,000 μL (Volumes over 100 μL are delivered in multiple aliquots. Maximum aliquot volume is 100 μL)
Specimen Tube Size 10 to 13 mm tubes
3 mL (10.25 x 64 mm) pediatric tubes
2 mL (13 x 47 or 50 mm) pediatric tubes
Specimen Tube Types Becton Dickinson Vacutainer* Tubes Worldwide
Becton Dickinson Glass Tubes with Hemogard*
Closure
Sarstedt
Sherwood Medical Tubes (Monoject)
Specimen Cassette Sizes Two sizes:
13 mm diameter tubes control tubes and pediatric size tubes in adaptors
16 mm diameter tubes
Carousel Tubes (Daughter Tubes) 12 x 75 mm straight polypropylene or polystyrene test tubes
Bar Code Symbologies

(Sample Identification)
Code 128 (USD-6)
Code 39
Interleaved 2 of 5 (also known as 12 of 5, USD-1 and USD-3)
Codabar (also known as USD-4 and NW7)

System Performance Accuracy (by weight)
 
Specification
Example Study Data
10 μL
9-12 μL
0.011
20 μL
18-22 μL
0.021
50 μL
47-53 μL
0.050
100 μL
95-105 μL
0.098
Precision
 
Specification (%CV)
Example Study Data(%CV)
10 μL
CV<10%
1.94%
20 μL
CV<10%
2.51%
50 μL
CV<5%
1.73%
100 μL
CV<5%
1.05%
Carryover
 
Range
Example Study Data
Fluorescence
<1%
0.0%
Primary Blood Sample
<1%
<0.08%
Throughput >80 daughter tubes per hour
Example data: 90 daughter tubes per hour in batch mode with tetraCXP (approx. 3 carousels per hour)
FP 1000 Height: 82 cm (32 in)
Width: 123 cm (48 in)
Depth: 77 cm (30 in)
Weight: 91 kg (200 lb)
Computer Height: 15.9 cm (6.2 in)
Width: 53.9 cm (21 in)
Depth: 43.0 cm (16.8 in)
Weight: 18.1 kg (40 lb)
Monitor Height: 43.1 cm (16.8 in)
Width: 40.8 cm (15.9 in)
Depth: 44.3 cm (17.3 in)
Weight: 22 kg (48.4 lb)
Power Requirements Installation Category - Over voltage Category II
Input Voltages - 100/240 Vac
Frequency - 48/62 Hz
Maximum Power - 150 W
Noise ≤ 65 db
Operating Temperatures 16 to 32° C (60 to 90° F)
Operating Humidity Range 30% to 85%, without condensation
Safety UL, CSA and CE
Pollution Degree 2
Altitude Up to 2,000 m
Workstation Computer Intel* Pentium* 4 microprocessor
Data Storage 3.5 in, 1.44 MB diskette drive
40 GB hard disk
52x (or higher) CD-ROM drive, MPCII compatible
750 MB ZIP* drive
Interfaces Windows* 2000 SP4
Bidirectional asynchronous serial interfaces for communication with mainframes and personal computers via Data Innovation's Instrument Manager*
Monitor SVGA flat-screen 17 inch color monitor
Communications One parallel port
Two USB ports
Onboard Ethernet network interface
Input Devices PS/2 optical IntelliMouse*
Standard IBM*-AT compatible 102 keyboard
Chumoto hand held bar code reader

*Vacutainer is a registered trademark, and Hemogard is a trademark of Becton, Dickinson and Company. Instrument Manager is a trademark of Data Innovations, Inc. ZIP is a registered trademark of Iomega Corporation. Windows and IntelliMouse are registered trademark of Microsoft Corporation. All trademarks are the property of their respective owners.

back to top

Additional Information:

 
 
Home | Products | Customer Support | Resource Center
Employment | Our Company | Contact Us | Site Map
 Privacy©1998 - 2008 Beckman Coulter, Inc.