Beckman Coulter, Inc.
 

Products

   
   
 
 

  ProteomeLabâ„¢ PA 800 Protein Characterization System

Printer Friendly


Related Product Information

 
ProteomeLabâ„¢ PA 800 Protein Characterization System. The ProteomeLab Solution for the Biopharmaceutical Industry.
From Development to Quality Control
The ProteomeLab Solution for the Biopharmaceutical Industry

Given the increasing acceptance for use of highly developed monoclonal antibodies as approved therapeutics, detailed characterization of these kinds of drugs is critically important. Therapeutic antibody quality analysis is essential to determine characteristics regarding purity, heterogeneity, and identity of these molecules. Additionally, quality analysis of the process by which they are manufactured is crucial. Beckman Coulter offers a robust platform with application at both the level of antibody R&D as well as antibody manufacturing, helping verify critical properties of not only the molecule itself but also those of the process by which it is produced. Unforeseen product breakdown or presence of impurities can jeopardize therapeutic efficacy as well as patient safety. Utilizing proven capillary electrophoresis technology and a number of validated methodologies, our automated characterization platform allows you to verify the state of your antibody molecule and its production environment helping you ensure it retains the properties with which it was developed.

Purity | Heterogeneity | Identification


Product Features
Click to enlarge image
SDS Gel MW Analysis Chemistry--SDS gel formulation offers molecular weight estimation across a broad range of protein sizes, superior to traditional protein electrophoresis methods.
SDS Gel MW Analysis Chemistry
  • Beckman Coulter's SDS gel formulation offers molecular weight estimation across a broad range of protein sizes and, in addition, allows for high resolution of low molecular weight species.
Click to enlarge image
The SDS-Gel MW analysis chemistry allows for high resolution separation in a replaceable gel format using UV or LIF detection, superior to traditional protein electrophoresis methods.
  • The SDS-Gel MW analysis chemistry allows for high resolution separation in a replaceable gel format. Whether it's a single protein moiety or a more complex sample, the PA 800 Protein Characterization System will allow you to separate proteins with sensitivity similar to that of Coomassie blue stained gels when using UV detection and silver stained gels when using LIF detection.
By determining a protein's isoelectric point, identity can be partially established. Isoelectric Focusing Chemistry
  • By determining a protein's isoelectric point, identity can be partially established. Heterogeneity can be assessed with quantitation of the different variants separated. Along with speed and automation advantages, the ProteomeLab PA 800 automated capillary isoelectric focusing (CIEF) offers direct quantification with on-line UV detection.
Carbohydrate Labeling and Analysis Chemistry, methods and controls needed for both oligosaccharide and monosaccharide analysis. Carbohydrate Labeling and Analysis Chemistry
  • The ProteomeLab Carbohydrate Labeling and Analysis Kit contains the reagents, methods and controls needed for both oligosaccharide and monosaccharide analysis.
Typical assay precision for antibodies analyzed using the IgG Purity and Heterogeneity Assay is <1% relative standard deviation. IgG Purity and Heterogeneity Chemistry
  • Typical assay precision for antibodies analyzed using the IgG Purity and Heterogeneity Assay is <1% relative standard deviation. This standard of reproducibility is similar for both reduced and non-reduced IgG samples.

More Info
Purity
You may think your monoclonal antibody is as pure as it's going to get. Or is it? The ProteomeLab PA 800 Protein Characterization System can help determine the presence of impurities present in either your end-product or in the process you're using to reach that point. Visualization of impurities can help track changes in molecular stability as well as those which may be present in manufacturing conditions.
Capillary electrophoresis (CE) technology offers you an alternative method to SDS-PAGE analysis for characterization of antibodies. Sensitivity similar to that of coomassie blue stained gels can be obtained using UV detection and similar to that of silver stained gels can be obtained using LIF detection. The highly resolving nature of CE also allows you to reveal protein species otherwise hidden using conventional techniques.
The IgG purity and heterogeneity chemistry, is able to resolve IgG isoforms that may be present due to degradation. With non-reduced IgG, the assay will resolve intact IgG from various isoforms including non-glycosylated IgG, 2 heavy chains and 1 light chain, 2 heavy chains, 1 heavy chain, and single light chains. With reduced IgG, the assay will resolve the IgG heavy chain, light chain, and non-glycosylated heavy chain. Additionally, any lower molecular weight impurities that fall between the heavy and light chains, and higher molecular weight impurities, larger than the intact heavy chain, can be resolved.
Impurities as a result of manufacturing processes and product modification can result in altered efficacy as well as risk to patient safety. Resolution between reduced antibody species and either low or high molecular weight impurities can be achieved.

 

Heterogeneity
Post translational modification of protein can be a desired characteristic but sometimes is an alarming one. Antibody modification may result in product heterogeneity and thus contamination of end-product. The ProteomeLab PA 800 Protein Characterization System allows for the analysis of heterogeneity effects on complete protein molecules and lets you characterize the microheterogeneity due to glycosylation.
Even seemingly pure antibody preparations may exhibit heterogeneity. Resolving this can help determine the presence of any differentially modified antibody species.

 

Glycosylation is an important post-translational modification providing stability, adhesion, and recognition properties to a given antibody. Differences in antibody glycosylation can alter their function and thus their efficacy. N-linked oligosaccharides obtained from PNGase F-catalyzed antibody hydrolysis can be labeled with APTS and analyzed using LIF
By determining differences in the isoelectric points of different antibodies, heterogeneity among lots as well as identity of species in those lots can be verified. Automated separation based on differences protein pI can easily show charge heterogeneity between two lots of antibody

 

Identification
Identification is important for complete molecular characterization. The ProteomeLab Protein Characterization System can be interfaced directly to mass spectrometry so online mass analysis can be performed.
Mass spectrometry can be an important component of the protein identification process. The ProteomeLab PA 800 Protein Characterization System is readily adaptable to MS systems so that protein characterization can be followed by online mass spectrometry to determine peptide mass-to-charge properties.
Compliance and Support
Training is an important part of efficient system operation. Beckman Coulter's qualified instructors will take new ProteomeLab PA 800 operators through a thorough and documented training process. If required, a documented maintenance and calibration course is available.
Beckman Coulter provides the tools to help you comply with regulations such as GLP and CGMP. IQ (InstallationQualification) and OQ (Operation Qualification) services are available for qualification of the ProteomeLab PA 800.