| Part No. |
Description |
| 500636
|
VersaRack™
Converts a miniature vial system to one which will count both miniature and standard vials. Includes a complete set of standard vial racks.
|
| 500637
|
VersaRack™
Converts a standard vial system to one which will count both miniature and standard vials. Includes a complete set of miniature vial racks.
|
| 500735
|
Xtalscint® CPM/DPM
Programmable coincidence gate and isotope window setting for maximum counting efficiency using either liquid or solid scintillators.
|
| 500734
|
Auto DPM
Automatic DPM calculation for single-label pure beta- and alpha-emitting isotopes without quench curves.
|
| 500629
|
H-Number Plus
External Quench Monitor (Cs-137) with Automatic Quench Compensation (AQC).
|
| 500657
|
Single-Label DPM
DPM calculations with pipetting monitor, quench curve set-up program, and correlation table. Manual editing and background quench curve set-up. With factory-stored H-3 and C-14 quench curves.
|
| 500625
|
Single- and Dual-Label DPM
Requires H-Number Plus (P/N 500629). DPM calculation with pipetting monitor, quench curve set-up program, and correlation table. Manual editing and background quench curve set-up. Factory-stored H-3 and C-14 quench curves.
|
| 500626
|
Single-, Dual-, and Triple-Label DPM
Requires H-Number Plus (P/N 500629). DPM calculation w/pipetting monitor, quench curve set-up program, correlation table. Manual editing/background quench curve set-up. With factory-stored H-3 and C-14 quench curves.
|
| 500660
|
Triple-Label DPM Upgrade
Upgrade from single- and dual-label DPM (P/N 500625) to triple-label DPM.
|
| 500623
|
Dual-Label % of Reference
Requires H-Number Plus (P/N 500629) and Dual- or Triple-Label DPM (P/N 500625 or 500626).
|
| 500621
|
Lum-Ex™
Luminescence Correction. Automatically corrects for luminescence interferences.
|
| 500656
|
Color Detection and Correction
Requires H-Number Plus (P/N 500629) and Single-, Dual-, or Triple-Label DPM (P/N 500657, 500625, or 500626). Automatic determination and correction of color and chemical quench contribution.
|
| 500624
|
Two-Phase Monitor
Requires H-Number Plus (P/N 500629). Monitors sample homogeneity at the time of counting and flags non-homogeneous samples on printout.
|
| 500633
|
Single-Photon Monitor
For detailed analysis of luminescence assays.
|
| 510620
|
Data Buffer & Transfer System
Internal buffer for data storage and 3.5 inch disk drive (720K/1.44MB). Data are transferred from the buffer to disk at the user's discretion and are stored in a variety of previously selected file formats.
|
| 510710
|
Radioactive Waste Manager
Requires Data Buffer and Transfer System (P/N 510620). Automatically tracks radioactive waste stream for each user. Half-life corrected total activity for each isotope is provided in printed reports.
|
| 501251
|
Hot Graph
Included in Color Monitor Systems. Real-time display of sample and Compton spectrum and histogram. Includes spectrum and histogram plot functions.
|
| 500622
|
Low Level Count Mode
"Decay Analysis" for Low Level applications. Significant reduction of background and increased sample throughput.
|
| 501252
|
Alpha/Beta Discrimination
Automatic separation of alpha and beta emitters using pulse shape discrimination (PSD) technique.
|
| 500638
|
User Programs, 30 Additional
Upgrades system from 20 to 50 user programs.
|
| 500736
|
RS-232 Interface
Includes user-selectable data and spectrum output.
|