DNA Synthesis Supplies: Quality and Convenience You Expect

Beckman Coulter's proven CED-phosphoramidite synthesis chemistry and packaging conveniences improve efficiencies and deliver higher yields. UltraFAST DNA Synthesis Technology reduces cleavage and deprotection time to just ten minutes and improves step-wise coupling efficiency. Phosphoramidite packaging includes activated molecular sieves to assure dryness and coupling efficiency. The cleavage and deprotection chemistry is provided in kits with syringes and vials that are compatible with Beckman Coulter reactor columns.

Quality and Convenience

Each reagent and phosphoramidite bottle is color-coded and clearly labeled to correspond directly with its position on the instrument. Augmented by dC-acetyl columns and amidites, Beckman Coulter's traditional CED-phosphoramidite chemistry significantly reduces the time it takes to acquire high-quality oligonucleotides.

  • Economical Mono-Pak and Binary-Pak™ phosphoramidites include molecular sieves to assure dryness, and a minimum of four weeks life on the instrument.
  • Single pore-size reactor columns used for both short and long oligonucleotides feature a zero dead volume design that minimizes reagent consumption.
  • Convenient cleavage and deprotection kits include UltraFAST chemistry that cleaves and deprotects in just ten minutes.

The nomenclature for the phosphoramidites and their protecting groups is as follows: Bz - benzoyl, Ac - acetyl, iBu - isobutyrl. Bz protects adenosine and standard cytidine. Ac protects UltraFAST cytidine. iBu protects guanosine. Thymidine and Inosine do not have protecting groups.

 

Reactor Columns, 1/Pack 

Single pore-size glass column supports with the first nucleotide covalently attached. Column threads directly onto the Oligo Series Synthesizers and are guaranteed to be suitable for the synthesis of both short and long oligonucleotides.

Reactor Columns, 30 nmole, 1/Pack 

Part No. Description
337719 Reactor Columns, dA(Bz), 30 nmole
337793 Reactor Columns, dC(Ac), 30 nmole
337721 Reactor Columns, dG(iBu), 30 nmole
337722 Reactor Columns, T, 30 nmole

Reactor Columns, 200 nmole, 1/Pack 

Part No. Description
337723 Reactor Columns, dA(Bz), 200 nmole
337795 Reactor Columns, dC(Ac), 200 nmole
337725 Reactor Columns, dG(iBu), 200 nmole
337726 Reactor Columns, T, 200 nmole

Binary-Pak™ CED-Phosphoramidites 

The phosphoramidite and acetonitrile are premeasured and packaged in a ready-to-mix bottle configuration containing activated molecular sieves, to provide extended life of at least four weeks on the instrument.

0.25 gram Binary-Paks 

Part No. Description
337737 Binary-Pak™ CED-Phosphoramidites, dA(Bz), 0.25 gram/5 mL Acetonitrile
337790 Binary-Pak™ CED-Phosphoramidites, dC(Ac), 0.25 gram/5 mL Acetonitrile
337739 Binary-Pak™ CED-Phosphoramidites, dG(iBu), 0.25 gram/5 mL Acetonitrile
337740 Binary-Pak™ CED-Phosphoramidites, T, 0.25 gram/5 mL Acetonitrile

0.5 gram Binary-Paks 

Part No. Description
337743 Binary-Pak™ CED-Phosphoramidites, dA(Bz), 0.5 gram/10 mL Acetonitrile
337791 Binary-Pak™ CED-Phosphoramidites, dC(Ac), 0.5 gram/10 mL Acetonitrile
337745 Binary-Pak™ CED-Phosphoramidites, dG(iBu), 0.5 gram/10 mL Acetonitrile
337746 Binary-Pak™ CED-Phosphoramidites, T, 0.5 gram/10 mL Acetonitrile

Mono-Pak™ CED-Phosphoramidites 

The phosphoramidite is packaged in a bottle containing activated molecular sieves for extended life of at least four weeks on the instrument. Requires acetonitrile (P/N 338161) for 0.5 g and 1.0 g sizes, respectively.

0.5 gram Mono-Paks 

Part No. Description
337704 Mono-Pak CED-Phosphoramidites, dA(Bz), 0.5 gram.
337705 Mono-Pak CED-Phosphoramidites, dC(Ac), 0.5 gram.
337706 Mono-Pak CED-Phosphoramidites, dG(iBu), 0.5 gram.
337707 Mono-Pak CED-Phosphoramidites, T, 0.5 gram.

1.0 gram Mono-Paks 

Part No. Description
337708 Mono-Pak CED-Phosphoramidites, dA(Bz), 1.0 gram.
337709 Mono-Pak CED-Phosphoramidites, dC(Ac), 1.0 gram.
337710 Mono-Pak CED-Phosphoramidites, dG(iBu), 1.0 gram.
337711 Mono-Pak CED-Phosphoramidites, T, 1.0 gram.

Other Synthesis Reagents 

Part No. Description
338161 Base Diluent, Acetonitrile, 45 mL in 100-mL Bottle
Used with Mono-Pak phosphoramidites at 50 mg/mL concentration. Includes activated molecular sieves to ensure dryness. <10 ppm water.
337731 DNA Synthesis Reagent Kit
Recommended for Oligo 1000 only. Includes: P/N 337732 Oxidize, 337733 DEblock, 337734 CAP 1, 337735 CAP 2, premeasured for simultaneous depletion and replenishment when used with the Oligo 1000.
338284 Activate
Used to convert the stable phosphoramidite into reactive species (0.5 M Tetrazole/ Acentonitrile).
338293 Oxidizer
Used to oxidize the phosphorous on each cycle (3% I2 in THF, pyridine, water).
338248 Deblock
Used to remove the trityl protecting group on the phosphoramidite (3% Trichloroacetic Acid in Dichloromethane).
338282 Cap 1 (Cap A Replacement)
Automatically combined with Cap 2 reagent during synthesis to terminate incomplete reaction sequences (10% Acetic Anhydride in Tetrahydrofuran, lutidine).
338295 Cap 2 (Cap B Replacement)
Automatically combined with Cap 1 reagent during synthesis to terminate incomplete reaction sequences (17% N-methyl-Imidizole/Tetrahydrofuran).

Post-Synthesis Reagents and Supplies 

Part No. Description
607819 UltraFAST Cleavage and Deprotection Kit (set of 80)
Provides cleavage within 5 minutes at room temperature and deprotection within 5 minutes at 65°C. Includes 80 disposable syringes, 80 vials specially adapted with O-rings compatible with ammonia methylamine (AMA), and sufficient AMA to process 80 oligonucleotides synthesized at either 30 or 200 nmole scale or 40 oligonucleotides synthesized at 1,000 nmole scale.

Replacement Parts and Supplies 

Part No. Description
964338 10 Liter Waste Bottle
Polyethylene, fluorinated, split- and puncture-resistant bottle to use with Oligo 1000M or with the Oligo 1000 in place of the 4 liter bottle. Meets DOT-2T (Department of Trans- portation) specificationsto transport most hazardous reagents.
607909 Shield, Acetonitrile - Plastic acetonitrile safety container. Requires P/N 607838 Cap.

Replacement Parts 

Part No. Description
523198 RS-232 Cable - Straight-through, 25-pin serial cable (M-F) for X-Y plotter; 9 feet long. To link instrument to a personal computer for downloading sequences and for developing user-defined methods.
 

Pricing: For all items listed here, please contact your Beckman Coulter representative for pricing.

Certificates of Analysis: A Certificate of Analysis can be obtained for any of these reagents upon request.

Abbreviations: (Bz) - Benzoyl, (iBu) - isobutyryl, (Ac) - acetyl



  Note: Not all products are available in all countries.
 

 
 
Home | Products | Customer Support | Resource Center
Employment | Our Company | Contact Us | Site Map
 Privacy©1998 - 2009 Beckman Coulter, Inc.