Agarose slab gel electrophoresis has long been the typical method used
for the analysis of DNA and RNA. Although well established, it is time
consuming, labor intensive and only semi-quantitative at best. Capillary
gel electrophoresis offers an automated approach to nucleic acid
analysis with on-line detection that is fully quantitative, extending
the analytical capabilities of electrophoresis. Gels exist as polymers
in solution, allowing the user an environment which can easily be
optimized. Polymers in solution also allow for an automated mechanism of
gel loading and gel replacement. Beckman Coulter offers the following
nucleic acid kits useful for the routine analysis of oligonucleotides,
viral load determination, gene expression and the quantitative analysis
of DNA-protein interactions through mobility-shift assays.
|
|
eCAP ssDNA 100-R Kit
|
|
|
|
The eCAP ssDNA Kit is designed for the analysis of oligonucleotides,
providing a direct quantitative tool for quality control. This chemistry
utilizes linear polyacrylamide in solution to form a sieving gel, which
provides single base resolution of oligonucleotides between 10 and 100
bases. The neutral capillary provided with the kit has a stable,
physically bonded polyacrylamide coating, which eliminates
electroosmotic flow (EOF) and suppresses interactions of the sample with
the capillary wall. This chemistry utilizes a standard Tris-Borate EDTA
buffer system including high concentrations of urea to prevent secondary
structure formation. Applications of this kit have included DNA and RNA
probes, ribozymes and anti-sense phosphorothioate oligonucleotides. The
system is compatible with both UV and LIF detection systems to include
the assessment of fluorescent labels.
Kit includes coated capillaries (2), replaceable gel, and standards to
perform at least 70 runs. Urea denaturant is included separately,
enabling a naturing replaceable gel, if so desired.
|
| Part No. |
Description |
| 477480
|
eCAP™ ssDNA 100-R Kit
|
|
|
|
|
Analysis of 22-mer oligonucleotide
|
|
|
|
Analysis of 22-mer oligonucleotide; 300 V/cm and 30 C.
|
|
|
|
|
|
Separation of synthetic 17-mer oligonucleotide
|
|
|
|
Separation of synthetic 17-mer oligonucleotide with the trityl group
attached to the 5' end. Insert shows high-speed separation of the same
oligonucleotide accomplished using reverse injection from the short side
of the capillary.
|
|
|
|
|
|
Reorder Components
|
|
|
| Part No. |
Description |
| 477477
|
eCAP Neutral Capillary (DNA), 100 µm I.D., 65 cm total length, 12 cm
from window to outlet (quantity 1)
|
| 477621
|
ssDNA 100-R Polyacrylamide Gel (lyophilized) (quantity 1 g)
|
| 338481
|
Buffer Kit, includes: Tris Borate EDTA Buffer (2) and Urea 7 M (2)
|
| 477626
|
ssDNA 100-R Test Mix, Poly d(A) 40-60 Mer Oligonucleotides (containing
20 fragments) (quantity 0.2 O.D units)
|
|
|
|
|
eCAP dsDNA 1000 Kit
|
|
|
|
The eCAP dsDNA 1000 Kit is designed for the analysis of double-stranded
DNA fragments from 72 to 1000 base-pairs. This chemistry utilizes linear
polyacrylamide in solution to form a sieving gel. A neutral capillary
provided with this kit has a stable, physically bonded polyacrylamide
coating which eliminates electroosmotic flow (EOF) and suppresses
interactions of the sample with the capillary wall. This chemistry
utilizes a standard Tris-Borate EDTA buffer system and allows the
addition of intercalating dyes like ethidium bromide or our proprietary
EnhanCE™ to improve resolution and increase sensitivity. This kit is
ideal for the analysis of PCR* products which can be analyzed directly
with no sample clean-up. Applications of this kit have included gene
expression analysis (competitive PCR), direct hybridization viral load
determination (no amplification) and genotyping experiments with RFLPs,
STRs and AmFLPs. The system is compatible with both UV and LIF
detection, but LIF is recommended for most applications.
Kit includes: (2) 100 µm I.D. neutral capillaries (DNA), (3) vials of
replaceable polyacrylamide gel, (1) test mix consisting of Hae III
restriction digest f174 DNA containing 11 fragments from 72 bp to 1,353
bp, and instructions and methods for system set-up and analysis. For LIF
applications, we recommend the use of the intercalating dye EnhanCE.
|
|
|
|
|
|
Separation of an Hae III Restriction
|
|
|
|
Separation of an Hae III restriction digest of fX174 DNA using LIF
detection. Pressure injection for 10 seconds (10 µg/mL sample).
|
|
|
|
|
|
CE-LIF analysis of DNA products
|
|
|
|
CE-LIF analysis of DNA products generated by competitive RNA-PCR* of
cytochrome P450-1A1 mRNA in dioxin-treated HepG2 cells. Target sequence
is 367 bp; competitor is 228 bp; CF=carboxyfluorescein marker; IS=328 bp
internal standard.
|
|
|
|
|
|
Reorder Components
|
|
|
| Part No. |
Description |
| 477477
|
eCAP Neutral Capillary (DNA), 100 µm I.D., 65 cm total length, 12 cm
from window to outlet (quantity 1)
|
| 477628
|
dsDNA 1000 Polyacrylamide Gel Kit (lyophilized) (quantity: package of 3)
|
| 477414
|
dsDNA 1000 Test Mix, Hae III Restriction Digest fX174 DNA (quantity 20
ug)
|
| 477406
|
dsDNA 1000 Internal Standard, Orange G Reference Marker (quantity 1 mL)
|
|
|
|
|
Recommended
|
|
|
| Part No. |
Description |
| 477409
|
EnhanCE Dye (quantity 0.5 mL)
|
|
|
|
|
eCAP dsDNA 20,000 Kit
|
|
|
|
The eCAP dsDNA 20,000 Kit is designed for the analysis of
double-stranded DNA fragments from 1,000 to 20,000 base-pairs. This
chemistry utilizes linear polyacrylamide in solution to form a sieving
gel. A neutral capillary provided with this kit has a stable, physically
bonded polyacrylamide coating which eliminates electroosmotic flow (EOF)
and suppresses interactions of the sample with the capillary wall. This
chemistry utilizes a standard Tris-Borate EDTA buffer system and allows
the addition of intercalating dyes like ethidium bromide or our
proprietary EnhanCE, to improve resolution and increase sensitivity.
This kit is ideal for the analysis of large PCR* products or plasmids
and plasmid digests which can be analyzed directly with no sample
clean-up. The system is compatible with both UV and LIF detection.
Kit includes: (2) 100 µm I.D. neutral capillaries (DNA), (3) vials of
replaceable polyacrylamide gel, (1) test mix consisting of Hind III
restriction digest of l DNA. Contains 8 fragments from 125 bp to 23,130
bp, and instructions and methods for system set-up and analysis. For LIF
applications, we recommend the use of the intercalating dye EnhanCE.
|
| Part No. |
Description |
| 477486
|
eCAP dsDNA 20,000 Kit
|
|
|
|
|
|
|
|
|
Before and after separations of DNA fragments derived from the complete
EcoR1 digestion of a 12 Kbp plasmid vs. the undigested plasma itself.
|
|
|
|
|
|
Reorder Components
|
|
|
| Part No. |
Description |
| 477477
|
eCAP Neutral Capillary, 50 µm I.D., 45 cm total length, 14 cm from
window to outlet (quantity 1)
|
| 477485
|
dsDNA 20,000 Polyacrylamide Gel Kit (lyophilized) (quantity: package of
3)
|
| 477483
|
eCAP Test Mix, Hind III Digest 8 fragments from 125 to 23,130 base pairs
(quantity 500 µl)
|
| 477406
|
dsDNA 1000 Internal Standard, Orange G Reference Marker, (quantity 1 mL)
|
|
|
|
|
Recommended
|
|
|
| Part No. |
Description |
| 477409
|
EnhanCE Dye (quantity 0.5 mL)
|
|
|
|
|